TrimLine Series NP33
Air-Cooled Panel-Mounted Air Conditioners
download product information
Download
Product
Information

These products have undergone a design update. The older models are no longer available.

Legacy products are no longer in normal production. Consult factory for availability.
We recommend current series Guardian, GuardianX or Slimkool  as possible alternatives.
TECHNICAL DATA

Click to
Request
Quote
ModelNEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzRunning
Amps
Approx.
Weight
°F°C
Max./Min.Max./Min.lbskg
KA4C4NP33L12Listed40002770125/5052/10115/10060/509.3/10.09041
K2A4C4NP33L12Listed40002283120/5049/10230/20060/505.59041
Rating shown is for operation at maximum ambient temperature.
Fuse Amps for these units are 15.

Click on image for larger view
NEMA TYPE 12
MAINTAINED

TECHNICAL DATA

Click to
Request
Quote:
Model
Number:
KA4C4NP33LK2A4C4NP33L
NEMA
Rating:
1212
UL/CUL
Listed or
Recognized:
ListedListed
BTU/H
Capacity:
40004000
95/95 Rating
BTU/H:
27702283
Ambient
Temp °.F
Max./Min.:
125/50120/50
Ambient
Temp °.C
Max./Min.:
52/1049/10
Volts:115/100230/200
Hz:60/5060/50
Running
Amps:
9.3/10.05.5
Approx.
Weight lbs.:
9090
Approx.
Weight kg.:
4141
Rating shown is for operation at maximum ambient temperature.
Fuse Amps for these units are 15.

STANDARD FEATURES

  • Baked Powder Finish
  • Built-in Condensate Evaporator
    • Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
  • CFC-Free Refrigerant
    • CFC-free R134a Refrigerant is used
  • Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Compressor Short Cycle Protector
    • Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
  • Filter
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Low Ambient Kit
    • Maintains sufficient operating pressures when ambient temperatures drop below 50°F. Includes a compressor heater and a pressure device that senses the reduced discharge pressure and modulates the condenser blower. Effective to a minimum ambient temperature of 0°F.
  • NEMA 12 Rating Maintained (UL50)
    • All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
  • Programmable Temperature Alarm
    • All models feature a programmable temperature alarm to alert if early action is required.
  • Programmable Thermostat
    • All models feature a programmable thermostat, allowing more accurate and versatile performance features.
  • UL/CUL Listed

ACCESSORIES AND OPTIONS

  • Filter Recoating Adhesive
    • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
  • Internal Corrosion Protection
    • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Lead-Lag Controller
  • Lifting Eyes
    • Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
  • Remote Monitoring
    • An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
  • Remote Thermostat Relay
    • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
  • Special controls or indicators
  • Special materials or finishes
  • Special motors~ line cords or connectors
  • Stainless or Aluminum Shell

For NP33 models the part number is 12251F.

 

Enclosure Lights

Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details.

AIRFLOW
Click on image for larger view

PERFORMANCE

GENERAL ARRANGEMENT
Click on image for larger view


Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view


Dimensions, inches [mm], are for reference only and subject to change.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
BTU/H Rating
TrimLine NP2828.50 x 10.14 x 11.504000
TrimLine NP3636.75 x 15.06 x 12.254000-6000
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

GA Drawing

NP33 General Arrangement Drawing (OLD)
NP33 General Arrangement Drawing W/ Programmable T-stat

Installation Instructions

K_A4C4NP33L Installation Instructions
K_A4C4NP33L Installation Instructions (OLD)

Literature

Air Conditioner Quick-Sheet
Condensate Evaporator Kits
Condensation and Electronics
Electronic Enclosure Cooling With Special Purpose Air Conditioners
Hazardous Location Series White Paper
Increasing the Lifespan and Reliability of Electrical Components
KLLC100 Lead-Lag Controller (1 page)
Kooltronic Design Guide/Catalog (215 pages)
Kooltronic Standard Warranty
NEMA Enclosure Ratings
Short-Form Catalog (16 pages)

Operator's Manual

KLLC100 Lead-Lag Controller
KLLC480 Lead-Lag Controller
Trimline NP33 Operator's Manual (OLD)
Trimline NP33 Operator's Manual W/ Programmable T-stat

Wiring Diagram

K2A4C3NP33/56 Wiring Diagram (Ladder)
K2A4C4NP33L-3 Wiring Diagram (Ladder)
KA4C_NP33L, K2A4C_NP33L, K2A4C_NP33L5 Wiring Diagram (Ladder)
KAC_NP33, KAC_NP36, KAC_NP47 Wiring Diagram (Ladder)
KAC_NP33/56, KAC4NP36/56, KA4C4NP33/56 Wiring Diagram (Ladder)
KAC2NP33/50, KAC2NP36/50 Wiring Diagram (Ladder)
KAC3NP33/50-1 Wiring Diagram (Ladder)
KAC4C4NP33LY & LBY Wiring Diagram (Point-to-Point)
TrimLine Series K_A4C_NP33L, K2A4C_NP33L5 Wiring Diagram (Ladder)
TrimLine Series K_A4C4NP33L Wiring Diagram (Ladder) (W/DIXELL)
TrimLine Series K_A4C4NP33L Wiring Diagram (Ladder) (W/DIXELL)

Thursday, February 21, 2019  
© 1996-2019 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
sales@kooltronic.com
Popular links:

Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Inside Sales Persons
Kooltronic Blog
Search

air conditioners air conditioners