Intrepid Series EP56 Outdoor
Air-Cooled Panel-Mounted Air Conditioners

download product information
Download
Product
Information
TECHNICAL DATA

Click to
Request
Quote
ModelBTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzCooling
Amps
Heating
Amps
Approx.
Weight
°F°C
Max./Min.Max./Min.lbskg
Request RFQ linkK2A6C30EP56TR3000028000131/055/-172306025.515.3302138
Request RFQ linkK2A6C30EP56BR3000028000131/055/-172306025.515.3304139
230V models with Short Cycle Protector are not RoHS compliant.
TR in model number is Top Evaporator Discharge.
BR in model number is Bottom Evaporator Discharge.
Cooling Amps for both units are 25.5.
Heating Amps for both units are 15.3.

Click on image for larger view
Intrepid EP56 Air Conditioner photo
NEMA TYPE 3R, 12 & 1
MAINTAINED

TECHNICAL DATA

Click to
Request
Quote:
Request RFQ linkRequest RFQ link
Model
Number:
K2A6C30EP56TRK2A6C30EP56BR
BTU/H
Capacity:
3000030000
95/95 Rating
BTU/H:
2800028000
Ambient
Temp °.F
Max./Min.:
131/0131/0
Ambient
Temp °.C
Max./Min.:
55/-1755/-17
Volts:230230
Hz:6060
Cooling
Amps:
25.525.5
Heating
Amps:
15.315.3
Approx.
Weight lbs.:
302304
Approx.
Weight kg.:
138139
230V models with Short Cycle Protector are not RoHS compliant.
TR in model number is Top Evaporator Discharge.
BR in model number is Bottom Evaporator Discharge.
Cooling Amps for both units are 25.5.
Heating Amps for both units are 15.3.

STANDARD FEATURES

  • Available in either top or bottom evaporator air discharge model
  • Baked Powder Finish
  • Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Condenser Blower Speed Controller
    • A speed control sensing bulb located in the condenser air outlet area switches the condenser blower between minimum and maximum speed based on the ambient temperature. This reduces noise levels, fan cycling, compressor cycling and prevents the unit from freezing.
  • Crankcase Compressor Heater
    • 120V or 240V heater attached to the compressor crankcase to maintain appropriate temperatures during cold operating conditions.
  • Heavy-Duty Steel Shell
  • Low Temperature Control Thermostat
    • Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
  • NEMA 12, 3R & 1 Ratings Maintained (UL50)
    • Fully gasketed for tight, leakproof installation, in compliance with the NEMA 12, 3R & 1 Enclosure Ratings.
  • Tamper-resistant hardware
  • UL/CUL Recognized
  • Zero ODP Refrigerant
    • R410a, an HFC having zero ozone depleting potential.

ACCESSORIES AND OPTIONS

  • Enclosure Heater
    • Eliminates damaging condensation, increasing reliability of electrical enclosure components.
  • Internal Corrosion Protection
    • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Click for more info.Lead-Lag Controller
  • Remote Thermostat Relay
    • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
  • Special paint finishes
  • Temperature Alarm
    • A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.

Enclosure Lights

AIRFLOW
Click on image for larger view

Intrepid EP56 Air Conditioner isometric illustration

PERFORMANCE

Intrepid EP56 Air Conditioner performance chart

GENERAL ARRANGEMENT
Click on image for larger view

Intrepid EP56 Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view

Intrepid EP56 Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
BTU/H Rating
Guardian DP60LV60.20 x 24.14 x 13.0220800-26000
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

  • 2-D Drawing of the Mounting Plan
    • K2A6C30EP56_R 2-D Drawing of the Mounting Plan
  • 3-D Solid Model
    • K2A6C30EP56_R 3-D Solid Model
  • Data Sheet
    • KLLC100-480 Lead-Lag Controller Product Data Sheet
    • EP56 Product Data Sheet
  • GA Drawing
    • EP56BR General Arrangement Drawing
    • K2A6C30EP56TR-4 General Arrangement Drawing
  • Installation Instructions
    • K2A6C30EP56BR Installation Instructions (2 pages)
    • K2A6C30EP56TR Installation Instructions (2 pages)
  • Literature
    • Air Conditioner Quick-Sheet
    • Condensate Evaporator Kits
    • Condensation and Electronics
    • Electronic Enclosure Cooling With Special Purpose Air Conditioners
    • Hazardous Location Series White Paper
    • Increasing the Lifespan and Reliability of Electrical Components
    • KLLC100 Lead-Lag Controller (1 page)
    • Kooltronic Design Guide/Catalog (215 pages)
    • Kooltronic Standard Warranty
    • NEMA Enclosure Ratings
    • Short-Form Catalog (16 pages)
    • Airflow Switch Data Sheet
  • Operator's Manual
    • KLLC100 Lead-Lag Controller
    • KLLC480 Lead-Lag Controller
    • Intrepid EP56 Operator's Manual
    • K2A6C30EP56TR-4 Operator's Manual
  • Wiring Diagram
    • K2A6C30EP56_R Wiring Diagram (Ladder)
    • K2A6C30EP56_R Wiring Diagram (Point-to-Point)
    • K2A6C30EP56_R Wiring Diagram (Point-to-Point)
    • K2A6C30EP56_R Wiring Diagram (Point-to-Point)
    • K2A6C30EP56BR-2,-3 Wiring Diagram (Point-to-Point)
    • K2A6C30EP56TR-4 Wiring Diagram (Point-to-Point)
Footer logo
Thursday, December 12, 2019  
© 1996-2019 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
Contact Us
Popular links:

Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
Kooltronic Blog

Facebook icon YouTube icon Linked-In icon Twitter icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo