Home
MyKooltronic Account
U UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty

View Cart
RFQ
Your Quote Requests
You have no products to be quoted

View RFQ Cart
(609) 466-3400 Contact Us!
(609) 466-3400 Contact Us!
  • Products & Services
    • All Products
    • Air Conditioners
    • Centrifugal & Rack-Mount Blowers
    • Fans & Fan Trays
    • Heat Exchangers
    • Custom Cooling Design
    • Enclosure Accessories
    • Spare/Replacement Parts
    • Contract Manufacturing Services
  • Industries
    • All Industries
    • Battery Energy Storage Systems
    • Micro Data Centers
    • Kiosks, ATMs & Smart Lockers
    • Medical Technology
    • Wastewater & Water Treatment
    • Transportation
    • Industrial Manufacturing
    • Hazardous Locations
    • Food & Beverage
    • Military & Avionics
    • Critical Infrastructure
    • Security Detection & Surveillance
  • Sizing
  • Resources
    • Cooling Solutions Blog
    • MyKooltronic Customer Portal
    • Product Documentation
    • Whitepapers
    • An Intro to Closed Loop Cooling
    • Quality & Compliance Certficates ►
      • ISO 9001:2015 Certificate
      • UL Client Test Data Program Certificate
      • ROHS 3 Compliance Statement
      • REACH Declaration
      • Kooltronic Quality Policy
      • Conflict Minerals Report
      • CE Certificate of Conformity
    • Credit Application
    • Credit Reference Form
  • About Us
    • About Kooltronic
    • News & Announcements
    • Eco-Friendly Practices
    • Interactive Timeline
    • Virtual Tour
    • Our Core Values
    • Careers with Kooltronic
  • Contact Us
    • Send Us a Message
    • Sales Team
    • After Sale Kare (ASK)
  • Shopping Cart
  • RFQ Cart
  • MyKooltronic
{1}
##LOC[OK]##
{1}
##LOC[OK]## ##LOC[Cancel]##
{1}
##LOC[OK]## ##LOC[Cancel]##

KSEHT
Fan Heater with Thermostat

These compact high-performance fan heaters prevent formation of condensation and provide an evenly distributed interior air temperature in outdoor enclosures and control cabinets - especially under extreme climatic conditions. The foot mounting capability allows installation on the base panel of enclosures

These heaters feature brushed metal housings and include an auto fan control switch to prolong motor life. A pilot light indicates "Heat On" condition.

Product Photo Thumbnail
LightBox Active Image

Image 1 of 1
ce-crus-rohs logo
Select Model Type

ModelVoltageHzHeating
Power
(Watts)*
Airflow CFM**Dimensions
HxWxD (Inches)
Weight (lbs)
KSEHT12511550/60125165.5 x 4.0 x 4.51.8
KSEHT20011550/60200165.5 x 4.0 x 4.51.8
KSEHT40011550/60400267.5 x 4.0 x 4.53.0
KSEHT80011550/60800267.5 x 4.0 x 4.53.0
K2SEHT12523050/60125165.5 x 4.0 x 4.51.8
K2SEHT20023050/60200165.5 x 4.0 x 4.51.8
K2SEHT40023050/60400267.5 x 4.0 x 4.53.0
K2SEHT80023050/60800267.5 x 4.0 x 4.53.0
* At 50°F
** Free blowing.

TECHNICAL DATA

Model Number:
Voltage:
Hz:
Heating Power (Watts)*:
Airflow CFM**:
Dimensions HxWxD (Inches):
Weight (lbs):
KSEHT12511550/60125165.5 x 4.0 x 4.51.8
KSEHT20011550/60200165.5 x 4.0 x 4.51.8
KSEHT40011550/60400267.5 x 4.0 x 4.53.0
KSEHT80011550/60800267.5 x 4.0 x 4.53.0
K2SEHT12523050/60125165.5 x 4.0 x 4.51.8
K2SEHT20023050/60200165.5 x 4.0 x 4.51.8
K2SEHT40023050/60400267.5 x 4.0 x 4.53.0
K2SEHT80023050/60800267.5 x 4.0 x 4.53.0
* At 50°F
** Free blowing.
TECHNICAL DATA
Overheat protection:
Built-in temperature limiter
Temperature range:
-4°F to 104°F
Housing:
Brushed metal housing
Connection:3-pole terminal, AWG 14 max. (2.5 mm²)
Mounting:Screws (not included)
Mounting position:Vertical
UL Recognized File number:E358386 series 801

  • Standard Features
  • Arrangement
  • Applications
• Designed to prevent condensation
Designed to prevent condensation or maintain a minimum temperature inside an electrical enclosure
• Built-in thermostat (settings from 0°F to 100°F)
• Brushed metal housing
• Includes an auto fan control switch to prolong motor life
• Low weight and low maintenance
• Designed for easy panel mounting
• Pilot light for "Heat On" indication
• Integrated overheat protection
Click on image for larger view
General Arrangement Thumbnail
LightBox Active Image

Image 1 of 1
Fan Heater Thermostat general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

Dimensions, inches [mm], are for reference only and subject to change.
  • Data Sheet
    Kseht Fan Heater Data Sheet [295Kb]
  • Literature
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Custom Cooling Medical Flyer [211Kb]
    Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    Kooltronic Unit Longevity Press Release [167Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    KSEHT Cabinet Heater Instruction Sheet [205Kb]
    Airflow Switch Data Sheet [159Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
Electrical and Electronic enclosures
Telecommunications systems  
Display panels  
Personnel environmental booths  
Automatic teller machines (ATM's)  
Access & Parking control systems  
Ticket dispensers

Footer logo
Sunday, August 9, 2026  
©2026 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
609-466-1114 (fax)
Contact Us
Popular links:

Home
Product Sizing and Selection
Catalogs/Brochures
Sales Team
Careers
MyKooltronic

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo

Search