Traditional WP28 Series Water-Cooled
Panel-Mounted Air Conditioners (Discontinued)

download product information Download
Product
Information
These products are discontinued and no longer in production.
We recommend the Traditional Series as a possible alternative.
TECHNICAL DATA

Click to
Request
Quote
ModelBTU/H
Capacity
Water Flow (GPM)
@85°F Max.*
VoltsHzRunning
Amps
Approx.
Weight
lbskg
Request RFQ linkKA4C2WP2820001.0115/10060/509.89041
Request RFQ linkK2A4C2WP2820001.0230/20060/505.09041
Request RFQ linkKA4C3WP2830001.0115/10060/509.99041
Request RFQ linkK2A4C3WP2830001.0230605.29041
Request RFQ linkKA4C4WP2840001.01156010.09041
Request RFQ linkK2A4C4WP2840001.0230605.49041
Rated for full capacity load at 85°F water. Usage will vary at lower load or cooler water conditions.
Rating shown is for operation at maximum water temperature.

Click on image for larger view
WP28 (Discontinued) Air Conditioner photo

TECHNICAL DATA

Click to
Request
Quote:
Request RFQ linkRequest RFQ linkRequest RFQ linkRequest RFQ linkRequest RFQ linkRequest RFQ link
Model
Number:
KA4C2WP28K2A4C2WP28KA4C3WP28K2A4C3WP28KA4C4WP28K2A4C4WP28
BTU/H
Capacity:
200020003000300040004000
Water Flow (GPM)
@85°F Max.*
1.01.01.01.01.01.0
Volts:115/100230/200115/100230115230
Hz:60/5060/5060/50606060
Running
Amps:
9.85.09.95.210.05.4
Approx.
Weight lbs.:
909090909090
Approx.
Weight kg.:
414141414141
Rated for full capacity load at 85°F water. Usage will vary at lower load or cooler water conditions.
Rating shown is for operation at maximum water temperature.

STANDARD FEATURES

  • Baked Powder Finish
  • Ball-bearing Motors
    • All blower motors are UL/CSA Recognized and include automatic-reset thermal overload protection and double-sealed or double-shielded precision ball bearings. Special permanent lubricants perform over a broad temperature range: -20°F (-29°C) to 250°F (121°C). Tube axial fans are rated to perform at 14°F (-10°C) to 158°F (70°C) and are designed to meet UL, CSA and VDE.
  • Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Excess Pressure Control
  • Heavy-Duty Steel Shell
  • Low Temperature Control Thermostat
    • Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
  • Six-Foot [1.8m] (minimum) 3-Wire Power Cord
  • Water Regulating Valve

ACCESSORIES AND OPTIONS

  • Condensate Evaporator Kit
    • Condensate evaporator kits are available for attachment to the bottom of Air-Cooled Panel Mounted Air Conditioners. Condensate is collected, vaporized and discharged to the surrounding air. All units include a safety overflow drain which discharges excessive condensate when required. Overflow may occur when cabinets are poorly sealed, or when cabinet doors are frequently opened, permitting the invasion of moisture-laden air. Models: KCH30 (115v) or K2CH30 (230v)
  • Condenser Access Panel
    • Expressly designed for quick, convenient access to the condenser coil for easy cleaning and servicing. Recommended for units operating in dirty environments, the panel is easily removed and replaced by use of a few fasteners, without removal of the entire rear cover panel.
  • Deep Drain Pan Kit
  • Enclosure Heater
    • Eliminates damaging condensation, increasing reliability of electrical enclosure components.
  • Internal Corrosion Protection
    • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Lifting Eyes
    • Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
  • Low Airflow Detector
    • Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
  • Mounting Hinge
    • (Left-hand or Right-hand) Allows the air conditioner itself to be used as a cabinet door. (Caution: The cabinet must be able to support the full weight of the unit in open position.) Specify left-hand (LH) or right-hand (RH), determined by facing the mounting side of the unit.
  • Short Cycle Protector
    • Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
  • Special materials or finishes
  • Special motors, line cords or connectors
  • Stainless or Aluminum Shell

AIRFLOW
Click on image for larger view

WP28 (Discontinued) Air Conditioner isometric illustration

GENERAL ARRANGEMENT
Click on image for larger view

WP28 (Discontinued) Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view

WP28 (Discontinued) Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

DOCUMENTS

  • Data Sheet
    KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
    WP28 Product Data Sheet (Discontinued) [389Kb]
  • Installation Instructions
    Traditional P28 Installation Instructions [130Kb]
  • Literature
    Air Conditioner Quick-Sheet [105Kb]
    Condensate Evaporator Kits [241Kb]
    Condensation and Electronics [3983Kb]
    Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
    Hazardous Location Series White Paper [234Kb]
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    KLLC100 Lead-Lag Controller (1 page) [58Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    Airflow Switch Data Sheet [159Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
  • Operator's Manual
    KLLC100 Lead-Lag Controller [38Kb]
    KLLC480 Lead-Lag Controller [79Kb]
    Water-Cooled Panel-Mount Air Conditioner Operator's Manual [188Kb]
  • Wiring Diagram
    KA4C2-4WP28 & 36 Wiring Diagram [41Kb]
Footer logo
Sunday, March 7, 2021  
©2021 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
609-466-1114 (fax)
Contact Us
Popular links:

Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
MyKooltronic

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo