Home
MyKooltronic Account
U UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty

View Cart
RFQ
Your Quote Requests
You have no products to be quoted

View RFQ Cart
(609) 466-3400 Contact Us!
(609) 466-3400 Contact Us!
  • Products & Services
    • All Products
    • Air Conditioners
    • Centrifugal & Packaged Blowers
    • Fans and Fan Trays
    • Heat Exchangers
    • Custom Cooling Design
    • Enclosure Accessories
    • Spare/Replacement Parts
    • Contract Manufacturing Services
  • Industries
    • All Industries
    • Battery Energy Storage Systems
    • Kiosks, ATMs & Smart Lockers
    • Medical Technology
    • Wastewater & Water Treatment
    • Transportation
    • Industrial Manufacturing
    • Hazardous Locations
    • Food & Beverage
    • Military & Avionics
    • Infrastructure
    • Security Detection & Surveillance
  • Sizing
  • Resources
    • Cooling Solutions Blog
    • MyKooltronic Customer Portal
    • Product Documentation
    • White Papers
    • An Intro to Closed Loop Cooling
    • Quality & Compliance Certficates ►
      • ISO 9001:2015 Certificate
      • UL Client Test Data Program Certificate
      • ROHS 3 Compliance Statement
      • REACH Declaration
      • Kooltronic Quality Policy
      • Conflict Minerals Report
    • Credit Application
    • Credit Reference Form
  • About Us
    • About Kooltronic
    • News & Announcements
    • Eco-Friendly Practices
    • Interactive Timeline
    • Virtual Tour
    • Careers with Kooltronic
  • Contact Us
    • Send Us a Message
    • Sales Team
    • After Sale Kare (ASK)
  • RFQ Cart
  • MyKooltronic

Profile Series DP60 External Mount
Air-Cooled Panel-Mounted Air Conditioners

download product information Download
Product
Information
These products are discontinued and no longer in production.
We recommend the Guardian DP60 as a possible alternative.
TECHNICAL DATA

Click to
Request
Quote
ModelNEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzRunning
Amps
Approx.
Weight
Spare and
Replacement
Parts
°F°C
Max./Min.Max./Min.lbskg
n/aK2A3C26DP60L3R & 12Listed2600023000131/-2055/-2823060/5019.4262120Order Parts
Rating shown is for operation at maximum ambient temperature.
Air Conditioners using R22 refrigerant no longer being manufactured after January 1, 2010.

Click on image for larger view
Profile DP60 (Dis.) Air Conditioner photo
NEMA TYPE 12 & 3R
MAINTAINED

TECHNICAL DATA

Click to
Request
Quote:
n/a
Model
Number:
K2A3C26DP60L
NEMA
Rating:
3R & 12
UL/CUL
Listed or
Recognized:
Listed
BTU/H
Capacity:
26000
95/95 Rating
BTU/H:
23000
Ambient
Temp °.F
Max./Min.:
131/-20
Ambient
Temp °.C
Max./Min.:
55/-28
Volts:230
Hz:60/50
Running
Amps:
19.4
Approx.
Weight lbs.:
262
Approx.
Weight kg.:
120
Spare and Replacement PartsOrder Parts
Rating shown is for operation at maximum ambient temperature.
Air Conditioners using R22 refrigerant no longer being manufactured after January 1, 2010.

STANDARD FEATURES

  • Click for more info.Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Condenser Blower Controller
  • EMI/RFI Suppressor
    • EMI/RFI Suppressor minimizes transient line spikes during on/off cycling.
  • Epoxy-Coated Condenser Coil
    • This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Shell or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Filter
    • All Kooltronic filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reusable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacement filters are available and can be ordered online at kooltronic.com/spareparts.
  • Heavy-Duty Steel Shell
  • Low-ODP Refrigerant
    • CFC-free R134a Refrigerant is used in all air conditioners for which compatible compressors are available. All others contain low Ozone Depleting Potential (ODP) R22 Refrigerant. The model number reflects the refrigerant. A 4 between the A and C signifies R134a; a 3 signifies R22. Consult KOOLTRONIC for status at time of requirement.
  • Low Temperature Control Thermostat
    • Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
  • Mounts Externally
  • NEMA 12 & 3R Ratings Maintained (UL50)
    • All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 12 and 3R Enclosure Ratings.
  • Textured Baked Powder Finish
    • "BAKED POWDER FINISH: Durable, baked-on beige powder finish is standard. Other finishes are available.*

      * See Profile Indoor/Outdoor, Integrity NEMA 4/4X and Intrepid Series for different specifications applicable."

  • UL/CUL Listed

ACCESSORIES AND OPTIONS

  • Cooling Effect Detector
    • A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
  • Enclosure Heater
    • Eliminates damaging condensation, increasing reliability of electrical enclosure components.
  • Filter Recoating Adhesive
    • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
  • Internal Corrosion Protection
    • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Other voltages and frequencies
  • Remote Thermostat Relay
    • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
  • Replacement Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Special paint finishes
  • Stainless Steel Shell

Enclosure Lights

AIRFLOW
Click on image for larger view

Profile DP60 (Dis.) Air Conditioner isometric illustration

PERFORMANCE

Profile DP60 (Dis.) Air Conditioner performance chart

Profile DP60 (Dis.) Air Conditioner performance chart #2

GENERAL ARRANGEMENT
Click on image for larger view

Profile DP60 (Dis.) Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view

Profile DP60 (Dis.) Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
BTU/H Rating
Guardian DP5352.60 x 22.14 x 13.0214400-18000
Guardian DP6060.20 x 24.14 x 13.0226000
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

  • Data Sheet
    Profile Series DP60 Data Sheet [664Kb]
  • Literature
    Air Conditioner Quick-Sheet [105Kb]
    Condensate Evaporator Kits [241Kb]
    Condensation and Electronics [3983Kb]
    Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
    Hazardous Location Series White Paper [234Kb]
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    Slimkool Series Flyer [584Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Custom Cooling Medical Flyer [211Kb]
    Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    Kooltronic Unit Longevity Press Release [167Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    Airflow Switch Data Sheet [159Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
  • Operator's Manual
    KLLC100 Lead-Lag Controller [38Kb]
    KLLC480 Lead-Lag Controller [79Kb]
    Profile Series DP60 Operator's Manual [820Kb]
  • Wiring Diagram
    DP60L Wiring Diagram (Ladder) [55Kb]
Footer logo
Sunday, March 26, 2023  
©2023 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
609-466-1114 (fax)
Contact Us
Popular links:

Home
Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
MyKooltronic

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo