MyKooltronic Account
U
UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty
View Cart
RFQ
Your Quote Requests
You have no products to be quoted
View RFQ Cart
(609) 466-3400
Contact Us!
(609) 466-3400
Contact Us!
Toggle navigation
Products & Services
All Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Contract Manufacturing Services
Industries
All Industries
Battery Energy Storage Systems
Kiosks, ATMs & Smart Lockers
Medical Technology
Wastewater & Water Treatment
Transportation
Industrial Manufacturing
Hazardous Locations
Food & Beverage
Military & Avionics
Infrastructure
Security Detection & Surveillance
Sizing
Resources
Cooling Solutions Blog
MyKooltronic Customer Portal
Product Documentation
White Papers
An Intro to Closed Loop Cooling
Quality & Compliance Certficates ►
ISO 9001:2015 Certificate
UL Client Test Data Program Certificate
ROHS 3 Compliance Statement
REACH Declaration
Kooltronic Quality Policy
Conflict Minerals Report
Credit Application
Credit Reference Form
About Us
About Kooltronic
News & Announcements
Eco-Friendly Practices
Interactive Timeline
Virtual Tour
Careers with Kooltronic
Contact Us
Send Us a Message
Sales Team
After Sale Kare (ASK)
RFQ Cart
MyKooltronic
Traditional Series P59 Air-Cooled
Panel-Mounted Air Conditioners (Discontinued)
These products are discontinued and no longer in production.
We recommend current series
Profile
or
Trimline
as possible alternatives.
Close
Image 1 of 1
Maximize image
Restore image
NEMA
TYPE 12
MAINTAINED
Select Model Type
Electrical (Volts/Hz):
115/60
100/50
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
KA3C12P59R
12
Listed
12000
7900
131/50
55/10
115/100
60/50
19
155
71
Rating shown is for operation at maximum ambient temperature.
Air Conditioners using R22 refrigerant no longer being manufactured after January 1, 2010.
TECHNICAL DATA
Model
NEMA
Rating
BTU/H
Capacity
Volts/Hz
KA3C12P59R
12
12000
115/60V, 60/50Hz
UL/CUL Listed or Recognized: Listed
95/95 BTU Rating: 7900
Ambient Max./Min. °F: 131/50
Ambient Max./Min. °C: 55/10
Running Amps: 19
Approx. weight: 155 lbs. (70 kg)
Rating shown is for operation at maximum ambient temperature.
Air Conditioners using R22 refrigerant no longer being manufactured after January 1, 2010.
Standard Features
Accessories & Options
Airflow Diagram
Performance
Arrangement
Similar Models
Documents
•
CFC-Free or Low-ODP Refrigerant
CFC-free R134a Refrigerant is used in all air conditioners for which compatible compressors are available. All others contain low Ozone Depleting Potential (ODP) R22 Refrigerant. The model number reflects the refrigerant. A 4 between the A and C signifies R134a; a 3 signifies R22. Consult KOOLTRONIC for status at time of requirement.
•
Filter
All Kooltronic filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reusable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacement filters are available and can be ordered online at kooltronic.com/spareparts.
•
Low Temperature Control Thermostat
Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
•
NEMA 12 Rating Maintained (UL50)
All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
•
Reversible Condenser Outlet Blower
•
UL/CUL Listed/ Recognized*
All models are UL/CUL Listed.
•
Aluminum Shell
Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
•
Condensate Evaporator Kit
Condensate evaporator kits are available for attachment to the bottom of Air-Cooled Panel Mounted Air Conditioners. Condensate is collected, vaporized and discharged to the surrounding air. All units include a safety overflow drain which discharges excessive condensate when required. Overflow may occur when cabinets are poorly sealed, or when cabinet doors are frequently opened, permitting the invasion of moisture-laden air. Models: KCH30 (115v) or K2CH30 (230v)
•
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
•
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
•
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
•
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
•
Low Airflow Detector
Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
•
Low Ambient Kit
Maintains sufficient operating pressures when ambient temperatures drop below 50°F. Includes a compressor heater and a pressure device that senses the reduced discharge pressure and modulates the condenser blower. Effective to a minimum ambient temperature of 0°F.
•
Mounting Hinge
(Left-hand or Right-hand) Allows the air conditioner itself to be used as a cabinet door. (Caution: The cabinet must be able to support the full weight of the unit in open position.) Specify left-hand (LH) or right-hand (RH), determined by facing the mounting side of the unit.
•
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
•
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
•
Short Cycle Protector
Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
•
Special motors~ line cords or connectors
•
Special paint finishes
•
Stainless Steel Shell
•
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Dimensions, inches [mm], are for reference only and subject to change.
Similar Models for this product family are not currently available. Please contact Customer Service for more information.
Data Sheet
P59D Product Data Sheet (Discontinued) [373Kb]
WP59 Product Data Sheet (Discontinued) (Discontinued) [387Kb]
GA Drawing
Large Panel-Mounted Air Conditioners General Arrangement Drawing [141Kb]
P59 General Arrangement Drawing [82Kb]
Installation Instructions
Traditional P47, P52, P59 Installation Instructions [125Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Slimkool Series Flyer [584Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller (Discontinued) [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
Traditional P47, P52, P59 Operator's Manual [166Kb]
Water-Cooled Panel-Mount Air Conditioner Operator's Manual (Discontinued) [188Kb]
Wiring Diagram
K2A4C12P47, K2A4C12P52, K2A4C12P59 (mfg. after Aug. 2001) Wiring Diagram (Ladder) [83Kb]
K2A4C12P47, K2A4C12P52, K2A4C12P59 (mfg. prior to Sept. 2001) Wiring Diagram (Ladder) [91Kb]
K2AC7SP59T/50-1, K2AC16P59T/50-3 Wiring Diagram (Ladder) [60Kb]
KAC_WP28, 36, 47, 52, 59 Wiring Diagram (Discontinued) [79Kb]