Integrity Series KNHX32 NEMA 4/4X
Air-to-Air Panel-Mounted Heat Exchangers
Download
Product
Information
TECHNICAL DATA
Click to
Request
Quote
Model
Volts
Power
Maximum Temperature °F
Performance
Watts/°F
(Air In)
Approx.
Weight
(lbs.)
Amps
Watts
Enclosure
Ambient
KNHX32
115
1.50
160
160
-20 to 131
21
70
K2NHX32
230
1.10
260
160
-20 to 131
21
70
60 Hz. operation. For 50 Hz. operation, consult Kooltronic.
Click on image for larger view
NEMA
TYPE 4/4X
MAINTAINED
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
KNHX32
K2NHX32
Volts:
115
230
Power, Amps:
1.50
1.10
Power, Watts:
160
260
Max Temp. °F
Enclosure:
160
160
Max Temp. °F
Ambient:
-20 to 131
-20 to 131
Perforamce
Watts/°F (Air in):
21
21
Approx.
Weight (lbs.):
70
70
60 Hz. operation. For 50 Hz. operation, consult Kooltronic.
STANDARD FEATURES
Closed-Loop Near-Ambient Cooling
Epoxy-coated convoluted aluminum element
Fabricated to the same standards as the uncoated convoluted aluminum elements, these are made from epoxy-coated aluminum stock that exceeds 1000 hour salt spray testing requirements.
Filter
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Gasketed Flanges
NEMA 4/4X Rating Maintained (UL50)
All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 4 and 4X Enclosure Ratings.
Stainless Steel Shell
For applications in corrosive or other hostile environments such as those requiring Internal Corrosion Resistant Coatings, especially where chemical/moisture combinations are present.
UL/CUL Listed
ACCESSORIES AND OPTIONS
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
Low Airflow Detector
Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
Other voltages and frequencies
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Special materials or finishes
Special motors, line cords or connectors
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
For
KNHX32
models the filter part number is
800F
.
AIRFLOW
Click on image for larger view
PERFORMANCE
GENERAL ARRANGEMENT
Click on image for larger view
GENERAL ARRANGEMENT
Click on image for larger view
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details
.
HOW TO ORDER
Specify model number. For 230 VAC operation, add a 2 after the K. Example: K2NHX32.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
Watts/°F
Integrity KNHX38
37.75 x 18.56 x 18.00
44-46
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
KNHX32 Product Data Sheet [78Kb]
GA Drawing
KNHX32 General Arrangement Drawing [65Kb]
Installation Instructions
KNHX32 Installation Instructions (2 pages) [131Kb]
Literature
Condensate Evaporator Kits [241Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
KLLC100 Lead-Lag Controller (1 page) [58Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Heat Exchanger Quick-Sheet [90Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
KNHX32 Operator's Manual [92Kb]