Home
MyKooltronic Account
U UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty

View Cart
RFQ
Your Quote Requests
You have no products to be quoted

View RFQ Cart
(609) 466-3400 Contact Us!
(609) 466-3400 Contact Us!
  • Products & Services
    • All Products
    • Air Conditioners
    • Centrifugal & Packaged Blowers
    • Fans and Fan Trays
    • Heat Exchangers
    • Custom Cooling Design
    • Enclosure Accessories
    • Spare/Replacement Parts
    • Contract Manufacturing Services
  • Industries
    • All Industries
    • Battery Energy Storage Systems
    • Kiosks, ATMs & Smart Lockers
    • Medical Technology
    • Wastewater & Water Treatment
    • Transportation
    • Industrial Manufacturing
    • Hazardous Locations
    • Food & Beverage
    • Military & Avionics
    • Infrastructure
    • Security Detection & Surveillance
  • Sizing
  • Resources
    • Cooling Solutions Blog
    • MyKooltronic Customer Portal
    • Product Documentation
    • White Papers
    • An Intro to Closed Loop Cooling
    • Quality & Compliance Certficates ►
      • ISO 9001:2015 Certificate
      • UL Client Test Data Program Certificate
      • ROHS 3 Compliance Statement
      • REACH Declaration
      • Kooltronic Quality Policy
      • Conflict Minerals Report
    • Credit Application
    • Credit Reference Form
  • About Us
    • About Kooltronic
    • News & Announcements
    • Eco-Friendly Practices
    • Interactive Timeline
    • Virtual Tour
    • Careers with Kooltronic
  • Contact Us
    • Send Us a Message
    • Sales Team
    • After Sale Kare (ASK)
  • RFQ Cart
  • MyKooltronic

KXHE122A Air-to-Air
Panel-Mounted Heat Exchangers

download product information Download
Product
Information
TECHNICAL DATA

Click to
Request
Quote
ModelVoltsPowerMaximum Temperature °FPerformance
Watts/°F
(Air In)
Approx.
Weight
(lbs.)
Spare and
Replacement
Parts
AmpsWattsEnclosureAmbient
Request RFQ linkKXHE122A1151.190160-20 to 1151930Order Parts
Request RFQ linkK2XHE122A2300.590160-20 to 1101930Order Parts
60 Hz. operation. For 50 Hz. operation, consult Kooltronic.

Click on image for larger view
KXHE122A Heat Exchanger photo
NEMA TYPE 12
MAINTAINED

TECHNICAL DATA

Click to
Request
Quote:
Request RFQ linkRequest RFQ link
Model
Number:
KXHE122AK2XHE122A
Volts:115230
Power, Amps:1.10.5
Power, Watts:9090
Max Temp. °F
Enclosure:
160160
Max Temp. °F
Ambient:
-20 to 115-20 to 110
Perforamce
Watts/°F (Air in):
1919
Approx.
Weight (lbs.):
3030
Spare and Replacement PartsOrder PartsOrder Parts
60 Hz. operation. For 50 Hz. operation, consult Kooltronic.

STANDARD FEATURES

  • Click for more info.Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Epoxy-coated element
    • Fabricated to the same standards as the uncoated convoluted aluminum elements, these are made from epoxy-coated aluminum stock that exceeds 1000 hour salt spray testing requirements.
  • Filter
    • All Kooltronic filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reusable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacement filters are available and can be ordered online at kooltronic.com/spareparts.
  • Heavy-Duty Steel Shell
  • NEMA 12 Rating Maintained (UL50)
    • All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
  • Refrigerant-Free Aluminum Element
  • UL/CUL Listed

ACCESSORIES AND OPTIONS

  • Filter Recoating Adhesive
    • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
  • Lifting Eyes
    • Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
  • Low Airflow Detector
    • Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
  • Mounting Hinge
    • (Left-hand or Right-hand) Allows the air conditioner itself to be used as a cabinet door. (Caution: The cabinet must be able to support the full weight of the unit in open position.) Specify left-hand (LH) or right-hand (RH), determined by facing the mounting side of the unit.
  • Other voltages and frequencies
  • Replacement Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Special materials or finishes
  • Special motors, line cords or connectors
  • Temperature Alarm
    • A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
  • Weather Protection Kit
    • For outdoor installations subject to invasion by rain, snow or windblown dirt, special deflectors shield the condenser air inlet and outlet ports. Air conditioners or heat exchangers installed outdoors may also require special exterior paint. NOTE: Units using the Weather Protection Kit are not UL Listed.

For KXHE122A models the filter part number is 100-3F.


AIRFLOW
Click on image for larger view

KXHE122A Heat Exchanger isometric illustration

PERFORMANCE

KXHE122A Heat Exchanger performance chart

GENERAL ARRANGEMENT
Click on image for larger view

KXHE122A Heat Exchanger general arrangement drawing
GENERAL ARRANGEMENT
Click on image for larger view

KXHE122A Heat Exchanger general arrangement drawing

Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details.
HOW TO ORDER
Specify model number. For 230 VAC operation, add a 2 after the K. Example: K2XHE122A.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
Watts/°F
KXHE120A24.00 x 11.50 x 4.1816
KXHE125A28.50 x 19.00 x 8.2557
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

  • Data Sheet
    KXHE125A, 125B, 240A, 245A, 360A & 365A Operator's Manual [401Kb]
    KXHE122A Product Data Sheet [111Kb]
  • GA Drawing
    KXHE122A General Arrangement Drawing [77Kb]
  • Installation Instructions
    KXHE120A, 120B & 122A Installation Instructions (2 pages) [86Kb]
  • Literature
    Condensate Evaporator Kits [241Kb]
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Custom Cooling Medical Flyer [211Kb]
    Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    Kooltronic Unit Longevity Press Release [167Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    Airflow Switch Data Sheet [159Kb]
    Heat Exchanger Quick-Sheet [90Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
  • Operator's Manual
    KLLC100 Lead-Lag Controller [38Kb]
    KLLC480 Lead-Lag Controller [79Kb]
    KXHE120A, KXHE120B & KXHE122A Operator's Manual [88Kb]
Footer logo
Sunday, March 26, 2023  
©2023 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
609-466-1114 (fax)
Contact Us
Popular links:

Home
Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
MyKooltronic

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo