Contact Us! 609-466-3400
Toggle navigation
Home
Products
All Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Product Documentation
Industries
All Industries
Self-Service Kiosk
Food & Beverage
Water Treatment
Industrial Manufacturing
Medical Technology
Infrastructure
Hazardous Locations
Security Detection
Sizing
About Us
About Kooltronic
Kooltronic and the Environment
Virtual Tour
Kooltronic Timeline
Quality Standards
Services
Careers with Kooltronic
Contact Us
Sales Team
Contact Us
After Sale
K
are (ASK)
Blog
Advantage Series
Air-Cooled Top-Mounted Air Conditioners
Download
Product
Information
TECHNICAL DATA
Click to
Request
Quote
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
K2A4C12RTL
3R & 12
Recognized
12000
7900
125/0
52/-17
230/208
60
8.7/9.3
140
64
K2A4C12RTL
3R & 12
Recognized
12000
7900
125/0
52/-17
200
50
8.5
140
64
KA4C12RTL
3R & 12
Recognized
12000
7900
120/0
49/-17
115/100
60/50
17.6/18.7
140
64
KA4C6RTL
3R & 12
Recognized
6000
4600
125/0
52/-17
115/100
60/50
14.6/14.3
131
60
K2A4C6RTL
3R & 12
Recognized
6000
4600
120/0
49/-17
230/208
60
6.3/7.0
131
60
K2A4C6RTL
3R & 12
Recognized
6000
4600
120/0
49/-17
220/200
50
5.6/6.0
131
60
Rating shown is for operation at maximum ambient temperature.
For Heating Amps, see Data Sheet.
Click on image for larger view
NEMA
TYPE 12 AND 3R
MAINTAINED
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
K2A4C12RTL
K2A4C12RTL
KA4C12RTL
KA4C6RTL
K2A4C6RTL
K2A4C6RTL
NEMA
Rating:
3R & 12
3R & 12
3R & 12
3R & 12
3R & 12
3R & 12
UL/CUL
Listed or
Recognized:
Recognized
Recognized
Recognized
Recognized
Recognized
Recognized
BTU/H
Capacity:
12000
12000
12000
6000
6000
6000
95/95 Rating
BTU/H:
7900
7900
7900
4600
4600
4600
Ambient
Temp °.F
Max./Min.:
125/0
125/0
120/0
125/0
120/0
120/0
Ambient
Temp °.C
Max./Min.:
52/-17
52/-17
49/-17
52/-17
49/-17
49/-17
Volts:
230/208
200
115/100
115/100
230/208
220/200
Hz:
60
50
60/50
60/50
60
50
Running
Amps:
8.7/9.3
8.5
17.6/18.7
14.6/14.3
6.3/7.0
5.6/6.0
Approx.
Weight lbs.:
140
140
140
131
131
131
Approx.
Weight kg.:
64
64
64
60
60
60
Rating shown is for operation at maximum ambient temperature.
For Heating Amps, see Data Sheet.
STANDARD FEATURES
CFC-Free Refrigerant
CFC-free R134a Refrigerant is used
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
Digital Temperature Display
Filter
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Head Pressure Control
A control device to minimize compressor cycling and prevent evaporator coil icing.
Low Ambient Kit
Maintains sufficient operating pressures when ambient temperatures drop below 50°F. Includes a compressor heater and a pressure device that senses the reduced discharge pressure and modulates the condenser blower. Effective to a minimum ambient temperature of 0°F.
Low Temperature Control Thermostat (except K2A4C12RTL)
NEMA 12 & 3R Ratings Maintained (UL50)
All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 12 and 3R Enclosure Ratings.
Painted Metal Grille
Programmable Thermostat (K2A4C12RTL)
UL/CUL Listed
ACCESSORIES AND OPTIONS
Aluminum Shell
Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
Compressor Short Cycle Protector
Available as a Standard Feature on models with Programmable Thermostat. Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Lead-Lag Controller
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
Remote Monitoring (K2A4C12RTL)
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Special materials or finishes
Special motors, line cords or connectors
Stainless Steel Shell
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
For
Advantage Series Top-Mount
models the filter part number is
10871F
.
Enclosure Lights
AIRFLOW
Click on image for larger view
PERFORMANCE
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details
.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
BTU/H Rating
Rack/Top-Mount H5
12.13 x 17.25 x 22.00
5000
Horizontal Super-Mini
9.06 x 14.00 x 16.00
2500
Top-Mount HT4
10.25 x 17.00 x 20.00
4000
Top-Mount H12
16.71 x 17.56 x 31.08
12000
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
2-D Drawing of the Mounting Plan
KA4C6-12RTL 2-D Drawing of the Mounting Plan [31Kb]
3-D Solid Model
KA4C6-12RTL 3-D Solid Model [6886Kb]
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
RT Product Data Sheet [117Kb]
GA Drawing
Advantage RT Top-Mounted General Arrangement Drawing [79Kb]
Installation Instructions
Advantage RT Top-Mounted Installation Instructions (2 pages) [181Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
KLLC100 Lead-Lag Controller (1 page) [58Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
Advantage RT Top-Mounted Operator's Manual (Pre-Dixell) [833Kb]
Advantage RT Top-Mounted Operator's Manual (w/Dixell) [675Kb]
KLLC100 Lead-Lag Controller [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
Wiring Diagram
K_A3C6RTL & K_A3C12RTL Wiring Diagram (Ladder) [46Kb]
K_A4C3RTL Wiring Diagram (Ladder) [57Kb]
K2A3C6RTL & K2A3C12RTL Wiring Diagram (Point-to-Point) [62Kb]
K2A4C12RTL Wiring Diagram (Ladder) (w/DIXELL) [58Kb]
K2A4C12RTL Wiring Diagram (Ladder) (w/DIXELL) [47Kb]
K2A4C6RTL Wiring Diagram (Point-to-Point) [59Kb]
K2A4C6RTL Wiring Diagram (Point-to-Point) [57Kb]
KA4C12RTL & KA4C12RTLY Wiring Diagram (Ladder) [54Kb]
KA4C12RTL & KA4C12RTLY Wiring Diagram (Point-to-Point) [57Kb]
KA4C12RTL Wiring Diagram (Ladder) [54Kb]
KA4C12RTL Wiring Diagram (Point-to-Point) [58Kb]
KA4C12RTL Wiring Diagram (Point-to-Point) [61Kb]
KA4C3RTL Wiring Diagram (Point-to-Point) [62Kb]
KA4C6RTL Wiring Diagram (Ladder) [56Kb]
KA4C6RTL Wiring Diagram (Ladder) [54Kb]
KA4C6RTL Wiring Diagram (Point-to-Point) [59Kb]
KA4C6RTLDK Wiring Diagram (Point-to-Point) [62Kb]
KA4C6RTLK Wiring Diagram (Point-to-Point) [58Kb]