Logo
Contact Us! 609-466-3400
  • Home
  • Products
    • Air Conditioners
    • Centrifugal & Packaged Blowers
    • Fans and Fan Trays
    • Heat Exchangers
    • Custom Cooling Design
    • Enclosure Accessories
    • Spare/Replacement Parts
    • Product Documentation
  • Industries
    • All Industries
    • Self-Service Kiosk
    • Food & Beverage
    • Water Treatment
    • Industrial Manufacturing
    • Medical Technology
    • Infrastructure
    • Hazardous Locations
  • Sizing
  • About Us
    • About Kooltronic
    • Kooltronic and the Environment
    • Virtual Tour
    • Kooltronic Timeline
    • Quality Standards
    • Services
    • Careers with Kooltronic
  • Contact Us
    • Sales Team
    • Contact Us
    • After Sale Kare (ASK)
  • Blog

Compact Series
Air-Cooled Top-Mounted Air Conditioners

download product information Download
Product
Information
TECHNICAL DATA

Click to
Request
Quote
ModelNEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzRunning
Amps
Approx.
Weight
°F°C
Max./Min.Max./Min.lbskg
Request RFQ linkKA4C4HTLRecognized40003442122/5050/10115/10060/5010.08539
Request RFQ linkK2A4C4HTLRecognized40002984125/5052/10230/20060/505.08539
Rating shown is for operation at maximum ambient temperature.
Fuse Amps for these units are 15.

Click on image for larger view
Top-Mount HT4 Air Conditioner photo

TECHNICAL DATA

Click to
Request
Quote:
Request RFQ linkRequest RFQ link
Model
Number:
KA4C4HTLK2A4C4HTL
NEMA
Rating:
UL/CUL
Listed or
Recognized:
RecognizedRecognized
BTU/H
Capacity:
40004000
95/95 Rating
BTU/H:
34422984
Ambient
Temp °.F
Max./Min.:
122/50125/50
Ambient
Temp °.C
Max./Min.:
50/1052/10
Volts:115/100230/200
Hz:60/5060/50
Running
Amps:
10.05.0
Approx.
Weight lbs.:
8585
Approx.
Weight kg.:
3939
Rating shown is for operation at maximum ambient temperature.
Fuse Amps for these units are 15.

STANDARD FEATURES

  • Built-in Condensate Evaporator
    • Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
  • CFC-Free Refrigerant
    • CFC-free R134a Refrigerant is used
  • Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Compressor Short Cycle Protector
    • Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
  • Filter
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Low Ambient Kit
    • Maintains sufficient operating pressures when ambient temperatures drop below 50°F. Includes a compressor heater and a pressure device that senses the reduced discharge pressure and modulates the condenser blower. Effective to a minimum ambient temperature of 0°F.
  • Programmable Temperature Alarm
    • All models feature a programmable temperature alarm to alert if early action is required.
  • Programmable Thermostat
    • All models feature a programmable thermostat, allowing more accurate and versatile performance features.
  • UL/CUL Recognized

ACCESSORIES AND OPTIONS

  • Filter Recoating Adhesive
    • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
  • Internal Corrosion Protection
    • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Click for more info.Lead-Lag Controller
  • Lifting Eyes
    • Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
  • Remote Monitoring
    • An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
  • Remote Thermostat Relay
    • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
  • Replacement Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Special controls or indicators
  • Special materials or finishes
  • Special motors, line cords or connectors
  • Stainless or Aluminum Shell

For Compact models the filter part number is 7131F.

Enclosure Lights

AIRFLOW
Click on image for larger view

Top-Mount HT4 Air Conditioner isometric illustration

PERFORMANCE

Top-Mount HT4 Air Conditioner performance chart

GENERAL ARRANGEMENT
Click on image for larger view

Top-Mount HT4 Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view

Top-Mount HT4 Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
BTU/H Rating
Rack/Top-Mount H512.13 x 17.25 x 22.005000
Horizontal Super-Mini9.06 x 14.00 x 16.002500
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

  • Data Sheet
    KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
    HT Top-Mounted Data Sheet [420Kb]
  • GA Drawing
    Compact HT (1,000-4,000 BTU/H) General Arrangement Drawing (OLD) [77Kb]
    Compact HT General Arrangement Drawing W/ Programmable T-stat [254Kb]
  • Installation Instructions
    K_A4C4HTL Installation Instructions (2 pages) [154Kb]
    K_A4C4HTL Installation Instructions (2 pages) W/ Programmable T-stat [163Kb]
  • Literature
    Air Conditioner Quick-Sheet [105Kb]
    Condensate Evaporator Kits [241Kb]
    Condensation and Electronics [3983Kb]
    Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
    Hazardous Location Series White Paper [234Kb]
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    KLLC100 Lead-Lag Controller (1 page) [58Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    Airflow Switch Data Sheet [159Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
  • Operator's Manual
    KLLC100 Lead-Lag Controller [38Kb]
    KLLC480 Lead-Lag Controller [79Kb]
    HT Top-Mounted Operator's Manual (1,000-4,000 BTU/H) (OLD) [168Kb]
    HT Top-Mounted Operator's Manual W/ Programmable T-stat [708Kb]
  • Wiring Diagram
    K_A4C4HTL Wiring Diagram (Ladder) (W/DIXELL) [48Kb]
    K_A4C4HTL Wiring Diagram (Ladder) (W/DIXELL) [47Kb]
    K_A4C4HTL Wiring Diagram (Point-to-Point) (W/DIXELL) [58Kb]
    K_A4C4HTL Wiring Diagram (Point-to-Point) (W/DIXELL) (NEW) [55Kb]
    K_A4C4HTL Wiring Diagram (Point-to-Point) (W/DIXELL) (NEW) [56Kb]
    KA4C1-5P24L, KA4C1-4HTL Wiring Diagram (Ladder) [67Kb]
    K2A3C2HTT/56 Wiring Diagram (Ladder) [73Kb]
    KAC 1 THRU 4 HT Wiring Diagram (Ladder) [80Kb]
    K_A4C_HS, KA4C_MMT, K_A4C_HTT, KA4C_NP17, KA4C_NM Wiring Diagram (Ladder)for NP17 units w/ s/n's up to A17A0030 & NP17 units w/ s/n's up to M16A4171 [69Kb]
    K2A4C_NP17, K2A4C2.0NM & K2A4C_HTT Wiring Diagram (Ladder) for NP17 units w/ s/n's up to M16A4171 [67Kb]
    KA4C2.0NM, KA4C_NP17, KA4C_MMT, KA4C_HTT Wiring Diagram (Ladder) for Micro-Mini units w/ s/n's up to A17A0030 [60Kb]
Footer logo
Wednesday, January 27, 2021  
©2021 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
Contact Us
Popular links:

Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
Kooltronic Blog

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo