Contact Us! 609-466-3400
Toggle navigation
Home
Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Product Documentation
Industries
All Industries
Self-Service Kiosk
Food & Beverage
Water Treatment
Industrial Manufacturing
Medical Technology
Infrastructure
Hazardous Locations
Sizing
About Us
About Kooltronic
Kooltronic and the Environment
Virtual Tour
Kooltronic Timeline
Quality Standards
Services
Careers with Kooltronic
Contact Us
Sales Team
Contact Us
After Sale
K
are (ASK)
Blog
TrimLine Series NP59
Air-Cooled Panel-Mounted Air Conditioners
Download
Product
Information
These products are discontinued and no longer in production.
We recommend the
Trimline Series
as a possible alternative.
TECHNICAL DATA
Click to
Request
Quote
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
K2A3C16NP59R
12
Recognized
16000
12500
125/50
52/10
230/200
60/50
22.0/22.3
250
114
K2A3C16NP59R5
12
Recognized
16000
12500
125/50
52/10
230
50
19.8
250
114
K2A3C24TP59R
12
Recognized
24000
0
125/50
52/10
230/200
60/50
22.0/22.3
265
121
Rating shown is for operation at maximum ambient temperature.
Air Conditioners using R22 refrigerant no longer being manufactured after January 1, 2010.
"For replacement units we recommend either the Guardian Series
DP50
or
DP53
"
Click on image for larger view
NEMA
NEMA 12, 3R & 4
MAINTAINED
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
K2A3C16NP59R
K2A3C16NP59R5
K2A3C24TP59R
NEMA
Rating:
12
12
12
UL/CUL
Listed or
Recognized:
Recognized
Recognized
Recognized
BTU/H
Capacity:
16000
16000
24000
95/95 Rating
BTU/H:
12500
12500
0
Ambient
Temp °.F
Max./Min.:
125/50
125/50
125/50
Ambient
Temp °.C
Max./Min.:
52/10
52/10
52/10
Volts:
230/200
230
230/200
Hz:
60/50
50
60/50
Running
Amps:
22.0/22.3
19.8
22.0/22.3
Approx.
Weight lbs.:
250
250
265
Approx.
Weight kg.:
114
114
121
Rating shown is for operation at maximum ambient temperature.
Air Conditioners using R22 refrigerant no longer being manufactured after January 1, 2010.
"For replacement units we recommend either the Guardian Series
DP50
or
DP53
"
STANDARD FEATURES
Built-in Condensate Evaporator
Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
EMI/RFI Suppressor
EMI/RFI Suppressor minimizes transient line spikes during on/off cycling.
Filter
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Low-ODP Refrigerant
CFC-free R134a Refrigerant is used in all air conditioners for which compatible compressors are available. All others contain low Ozone Depleting Potential (ODP) R22 Refrigerant. The model number reflects the refrigerant. A 4 between the A and C signifies R134a; a 3 signifies R22. Consult KOOLTRONIC for status at time of requirement.
Low Temperature Control Thermostat
Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
M/TAB Mounting System
NEMA 12 Rating Maintained (UL50)
All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
Reversible Condenser Outlet Blower
UL/CUL Recognized
ACCESSORIES AND OPTIONS
Aluminum Shell
Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
Cooling Effect Detector
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Lead-Lag Controller
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
Low Ambient Kit
Maintains sufficient operating pressures when ambient temperatures drop below 50°F. Includes a compressor heater and a pressure device that senses the reduced discharge pressure and modulates the condenser blower. Effective to a minimum ambient temperature of 0°F.
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Short Cycle Protector
Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
Special controls or indicators
Special motors~ line cords or connectors
Special paint finishes
Stainless Steel Shell
Weather Protection Kit
For outdoor installations subject to invasion by rain, snow or windblown dirt, special deflectors shield the condenser air inlet and outlet ports. Air conditioners or heat exchangers installed outdoors may also require special exterior paint. NOTE: Units using the Weather Protection Kit are not UL Listed.
Enclosure Lights
AIRFLOW
Click on image for larger view
PERFORMANCE
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
BTU/H Rating
Traditional P52
52.50 x 19.00 x 9.38
6000-12000
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
KCH20 & KCH30 Product Data Sheet [60Kb]
KXNP59 Product Data Sheet [75Kb]
GA Drawing
NP59 General Arrangement Drawing [150Kb]
KXNP59 General Arrangement Drawing [72Kb]
KXNP59 General Arrangement Drawing [227Kb]
Installation Instructions
K_XNP33, 36, 47 & 59 Installation Instructions (2 pages) [121Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
KLLC100 Lead-Lag Controller (1 page) [58Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
Trimline NP59 & TP59 Operator's Manual [165Kb]
KXNP Series Operator's Manual [82Kb]
Wiring Diagram
K2A3C14NP59R5-1 Wiring Diagram [88Kb]
K2AC16NP59-4, K2AC16NP59-5 Wiring Diagram [100Kb]
TP59/NP59, NP59-X116 Wiring Diagram [99Kb]