TECHNICAL DATA
Click to
Request
Quote
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
KA4C5RML
Listed
5000
4400
120/0
49/-17
115/100
60/50
15.0/14.5
97
45
K2A4C5RML
Listed
5000
4030
120/0
49/-17
230
50
6.8
97
45
K2A4C5RML
Listed
5000
4150
120/0
49/-17
230
60
7.8
97
45
Maximum ambient temperature is shown for Option 1 evaporator airflow. For other options maximum ambient temperature is 115ºF.
Rating shown is for operation at maximum ambient temperature.
Click on image for larger view
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
KA4C5RML
K2A4C5RML
K2A4C5RML
NEMA
Rating:
UL/CUL
Listed or
Recognized:
Listed
Listed
Listed
BTU/H
Capacity:
5000
5000
5000
95/95 Rating
BTU/H:
4400
4030
4150
Ambient
Temp °.F
Max./Min.:
120/0
120/0
120/0
Ambient
Temp °.C
Max./Min.:
49/-17
49/-17
49/-17
Volts:
115/100
230
230
Hz:
60/50
50
60
Running
Amps:
15.0/14.5
6.8
7.8
Approx.
Weight lbs.:
97
97
97
Approx.
Weight kg.:
45
45
45
Maximum ambient temperature is shown for Option 1 evaporator airflow. For other options maximum ambient temperature is 115ºF.
Rating shown is for operation at maximum ambient temperature.
STANDARD FEATURES
Baked Powder Finish
CFC-Free Refrigerant
CFC-free R134a Refrigerant is used
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
Compressor Short Cycle Protector
Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
Condenser Airflow at Front of Unit
The RML Series features condenser airflow at the front of the unit. This unique design eliminates the need for duct work, freeing up more space in the electronics cabinet. It also allows greater flexibility when locating a unit within an enclosure, and requires only one cutout on the enclosure. The RML is the only air conditioner on the market with this same-side condenser airflow configuration.
Customized airflow with supplied baffle plates
The RML Series offers a choice of up to five airflow patterns, allowing installation in any location within a data rack. Using supplied baffle plates the RML can easily be configured for a variety of applications.
EIA-notched flanges
Filter
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Heavy-Duty Steel Shell
Ideal for inconspicuous internal mounting
Programmable Temperature Alarm
All models feature a programmable temperature alarm to alert if early action is required.
Programmable Thermostat
All models feature a programmable thermostat, allowing more accurate and versatile performance features.
Six-Foot [1.8m] (minimum) 3-Wire Power Cord
UL/CUL Listed
ACCESSORIES AND OPTIONS
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Lead-Lag Controller
Other voltages and frequencies
Remote Monitoring
An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Special materials or finishes
Special motors, line cords or connectors
Stainless or Aluminum Shell
For
RML
models the filter part number is
8752F
.
Enclosure Lights
Miscellaneous
The RML Series offers a choice of up to five airflow patterns, allowing installation in any location within a data rack. Using supplied baffle plates the RML can easily be configured for a variety of applications.
AIRFLOW
Click on image for larger view
PERFORMANCE
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details
.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
BTU/H Rating
Rack/Top Mount H10
10.38 x 19.00 x 22.00
3500
Rack/Top Mount H9
10.38 x 19.00 x 22.00
3500
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
RML Data Sheet [576Kb]
GA Drawing
RML General Arrangement Drawing [125Kb]
RML General Arrangement Drawing W/ Programmable Thermostat [76Kb]
Installation Instructions
RML Series Air Conditioners Installation Instructions (2 pages) [238Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
KLLC100 Lead-Lag Controller (1 page) [58Kb]
RML Rack Mount Brochure [408Kb]
RML Rack Mount Flyer [189Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
Rack-Mounted RML Operator's Manual [831Kb]
Wiring Diagram
K_A4C5RML Wiring Diagram (Prgm. T-stat - Ladder) [48Kb]
K_A4C5RML Wiring Diagram (Prgm. T-stat - Point-to-Point) [69Kb]
K_A4C5RML Wiring Diagram (Prgm. T-stat - Point-to-Point) [70Kb]
K_A4C5RML Wiring Diagram (Low Temp. T-Stat - Ladder) [62Kb]
K2A4C5RML Wiring Diagram (Low Temp. T-Stat - Point-to-Point) [67Kb]
KA4C5RML Wiring Diagram (Low Temp. T-Stat Point-to-Point) [70Kb]