TrimLine Series NPT52
Air-Cooled Panel-Mounted Air Conditioners

download product information
Download
Product
Information
Legacy products are no longer in normal production. Consult factory for availability.
We recommend current series Guardian, GuardianX or Slimkool  as possible alternatives.
TECHNICAL DATA

Click to
Request
Quote
ModelNEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzRunning
Amps
Approx.
Weight
°F°C
Max./Min.Max./Min.lbskg
Request RFQ linkK2A6C16NPT52L12Listed1600013300125/-4052/-402306018.018986
Request RFQ linkK2A6C16NPT52L12Listed1600011300125/-4052/-402305018.018986
Rating shown is for operation at maximum ambient temperature.

Click on image for larger view
TrimLine NPT52 Air Conditioner photo
NEMA TYPE 12
MAINTAINED

TECHNICAL DATA

Click to
Request
Quote:
Request RFQ linkRequest RFQ link
Model
Number:
K2A6C16NPT52LK2A6C16NPT52L
NEMA
Rating:
1212
UL/CUL
Listed or
Recognized:
ListedListed
BTU/H
Capacity:
1600016000
95/95 Rating
BTU/H:
1330011300
Ambient
Temp °.F
Max./Min.:
125/-40125/-40
Ambient
Temp °.C
Max./Min.:
52/-4052/-40
Volts:230230
Hz:6050
Running
Amps:
18.018.0
Approx.
Weight lbs.:
189189
Approx.
Weight kg.:
8686
Rating shown is for operation at maximum ambient temperature.

STANDARD FEATURES

  • Built-in Condensate Evaporator
    • Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
  • Condenser Impeller Speed Controller
    • A solid state sensor reacting to the condenser coil temperature modulates the condenser impeller between minimum and maximum speed based on the coil temperature. This reduces noise levels, fan cycling, compressor cycling and prevents the unit from freezing.
  • Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Low Temperature Control Thermostat
    • Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
  • NEMA 12 Rating Maintained (UL50)
    • All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
  • UL/CUL Listed
  • Zero ODP Refrigerant
    • R410a, an HFC having zero ozone depleting potential.

ACCESSORIES AND OPTIONS

  • Aluminum Shell
    • Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
  • Compressor Short Cycle Protector
    • Available as a Standard Feature on models with Programmable Thermostat. Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
  • Enclosure Heater
    • Eliminates damaging condensation, increasing reliability of electrical enclosure components.
  • Filter Recoating Adhesive
    • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
  • Internal Corrosion Protection
    • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • Click for more info.Lead-Lag Controller
  • Remote Thermostat Relay
    • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
  • Replacement Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Special controls or indicators
  • Special motors~ line cords or connectors
  • Special paint finishes
  • Stainless Steel Shell
  • Temperature Alarm
    • A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.

For NPT52 models the filter part number is 9001F. The NPT52 uses two filters.


 

AIRFLOW
Click on image for larger view

TrimLine NPT52 Air Conditioner isometric illustration

PERFORMANCE

TrimLine NPT52 Air Conditioner performance chart

GENERAL ARRANGEMENT
Click on image for larger view

TrimLine NPT52 Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view

TrimLine NPT52 Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
BTU/H Rating
TrimLine NPT4747.25 x 15.06 x 12.257000-13000
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

  • Data Sheet
    • KLLC100-480 Lead-Lag Controller Product Data Sheet
    • NPT52 Product Data Sheet
  • GA Drawing
    • K2A6C16NPT52L General Arrangement Drawing
  • Installation Instructions
    • K2A6C16NPT52L Installation Instructions (2 pages)
  • Literature
    • Air Conditioner Quick-Sheet
    • Condensate Evaporator Kits
    • Condensation and Electronics
    • Electronic Enclosure Cooling With Special Purpose Air Conditioners
    • Hazardous Location Series White Paper
    • Increasing the Lifespan and Reliability of Electrical Components
    • KLLC100 Lead-Lag Controller (1 page)
    • Kooltronic Design Guide/Catalog (215 pages)
    • Kooltronic Standard Warranty
    • NEMA Enclosure Ratings
    • Short-Form Catalog (16 pages)
    • Airflow Switch Data Sheet
  • Operator's Manual
    • KLLC100 Lead-Lag Controller
    • KLLC480 Lead-Lag Controller
    • K2A6C16NPT52L Operator's Manual
  • Wiring Diagram
    • K2A6C16NPT52L & F Wiring Diagram (Point-to-Point)
    • K2A6C16NPT52L Wiring Diagram (Ladder)
    • K2A6C16NPT52L Wiring Diagram (Point-to-Point)
Footer logo
Thursday, December 12, 2019  
© 1996-2019 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
Contact Us
Popular links:

Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
Kooltronic Blog

Facebook icon YouTube icon Linked-In icon Twitter icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo