TrimLine Series NPT52
Air-Cooled Panel-Mounted Air Conditioners
Download
Product
Information
Legacy products are no longer in normal production. Consult factory for availability.
We recommend current series
Guardian
,
GuardianX
or
Slimkool
as possible alternatives.
TECHNICAL DATA
Click to
Request
Quote
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
K2A6C16NPT52L
12
Listed
16000
13300
125/-40
52/-40
230
60
18.0
189
86
K2A6C16NPT52L
12
Listed
16000
11300
125/-40
52/-40
230
50
18.0
189
86
Rating shown is for operation at maximum ambient temperature.
Click on image for larger view
NEMA
TYPE 12
MAINTAINED
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
K2A6C16NPT52L
K2A6C16NPT52L
NEMA
Rating:
12
12
UL/CUL
Listed or
Recognized:
Listed
Listed
BTU/H
Capacity:
16000
16000
95/95 Rating
BTU/H:
13300
11300
Ambient
Temp °.F
Max./Min.:
125/-40
125/-40
Ambient
Temp °.C
Max./Min.:
52/-40
52/-40
Volts:
230
230
Hz:
60
50
Running
Amps:
18.0
18.0
Approx.
Weight lbs.:
189
189
Approx.
Weight kg.:
86
86
Rating shown is for operation at maximum ambient temperature.
STANDARD FEATURES
Built-in Condensate Evaporator
Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
Condenser Impeller Speed Controller
A solid state sensor reacting to the condenser coil temperature modulates the condenser impeller between minimum and maximum speed based on the coil temperature. This reduces noise levels, fan cycling, compressor cycling and prevents the unit from freezing.
Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Low Temperature Control Thermostat
Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
NEMA 12 Rating Maintained (UL50)
All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
UL/CUL Listed
Zero ODP Refrigerant
R410a, an HFC having zero ozone depleting potential.
ACCESSORIES AND OPTIONS
Aluminum Shell
Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
Compressor Short Cycle Protector
Available as a Standard Feature on models with Programmable Thermostat. Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Lead-Lag Controller
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Special controls or indicators
Special motors~ line cords or connectors
Special paint finishes
Stainless Steel Shell
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
For
NPT52
models the filter part number is
9001F
. The
NPT52
uses two filters.
AIRFLOW
Click on image for larger view
PERFORMANCE
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
BTU/H Rating
TrimLine NPT47
47.25 x 15.06 x 12.25
7000-13000
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet
NPT52 Product Data Sheet
GA Drawing
K2A6C16NPT52L General Arrangement Drawing
Installation Instructions
K2A6C16NPT52L Installation Instructions (2 pages)
Literature
Air Conditioner Quick-Sheet
Condensate Evaporator Kits
Condensation and Electronics
Electronic Enclosure Cooling With Special Purpose Air Conditioners
Hazardous Location Series White Paper
Increasing the Lifespan and Reliability of Electrical Components
KLLC100 Lead-Lag Controller (1 page)
Kooltronic Design Guide/Catalog (215 pages)
Kooltronic Standard Warranty
NEMA Enclosure Ratings
Short-Form Catalog (16 pages)
Airflow Switch Data Sheet
Operator's Manual
KLLC100 Lead-Lag Controller
KLLC480 Lead-Lag Controller
K2A6C16NPT52L Operator's Manual
Wiring Diagram
K2A6C16NPT52L & F Wiring Diagram (Point-to-Point)
K2A6C16NPT52L Wiring Diagram (Ladder)
K2A6C16NPT52L Wiring Diagram (Point-to-Point)