MyKooltronic Account
U
UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty
View Cart
RFQ
Your Quote Requests
You have no products to be quoted
View RFQ Cart
(609) 466-3400
Contact Us!
(609) 466-3400
Contact Us!
Toggle navigation
Products & Services
All Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Contract Manufacturing Services
Industries
All Industries
Battery Energy Storage Systems
Kiosks, ATMs & Smart Lockers
Medical Technology
Wastewater & Water Treatment
Transportation
Industrial Manufacturing
Hazardous Locations
Food & Beverage
Military & Avionics
Infrastructure
Security Detection & Surveillance
Sizing
Resources
Cooling Solutions Blog
MyKooltronic Customer Portal
Product Documentation
Whitepapers
An Intro to Closed Loop Cooling
Quality & Compliance Certficates ►
ISO 9001:2015 Certificate
UL Client Test Data Program Certificate
ROHS 3 Compliance Statement
REACH Declaration
Kooltronic Quality Policy
Conflict Minerals Report
Credit Application
Credit Reference Form
About Us
About Kooltronic
News & Announcements
Eco-Friendly Practices
Interactive Timeline
Virtual Tour
Careers with Kooltronic
Contact Us
Send Us a Message
Sales Team
After Sale Kare (ASK)
RFQ Cart
MyKooltronic
Guardian DP43 NEMA 12, 3R & 4
Air-Cooled Panel-Mounted Air Conditioners
Close
Image 1 of 1
Maximize image
Restore image
NEMA
TYPE 12, 3R & 4
MAINTAINED
Select Model Type
Electrical (Volts/Hz):
115/60
115/50
230/60
200/50
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
KNA4C7DP43L
4
Listed
7000
5500
131/-20
55/-28
115
60/50
14.6/14.3
125
57
K2NA4C7DP43L
4
Listed
7000
5500
131/-20
55/-28
230/200
60/50
6.7/6.6
125
57
115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
Rating shown is for operation at maximum ambient temperature.
TECHNICAL DATA
Model
NEMA
Rating
BTU/H
Capacity
Volts/Hz
KNA4C7DP43L
4
7000
115/60V, 60/50Hz
UL/CUL Listed or Recognized: Listed
95/95 BTU Rating: 5500
Ambient Max./Min. °F: 131/-20
Ambient Max./Min. °C: 55/-29
Running Amps: 14.6/14.3
Approx. weight: 125 lbs. (57 kg)
K2NA4C7DP43L
4
7000
230/60V, 60/50Hz
UL/CUL Listed or Recognized: Listed
95/95 BTU Rating: 5500
Ambient Max./Min. °F: 131/-20
Ambient Max./Min. °C: 55/-29
Running Amps: 6.7/6.6
Approx. weight: 125 lbs. (57 kg)
115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
Rating shown is for operation at maximum ambient temperature.
This equipment is not intended for use in corrosive environments. Such use voids the warranty. The corrosion resistant coating option must be specified for equipment to be used in corrosive environments. This model is also available with a NEMA 4X rating as the
GuardianX DP43LV
which includes Internal Corrosion Protection and a Stainless Steel Shell as standard features.
Standard Features
Accessories & Options
Airflow Diagram
Performance
Arrangement
Similar Models
Documents
•
Baked Powder Finish
Heavy-duty steel shell with powder-baked finish (ANSI 61 gray). Custom color options are available.
•
Built-in Condensate Evaporator
Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
•
CFC-Free Refrigerant
CFC-free R134a Refrigerant is used
•
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
•
Compressor Short Cycle Protector
Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
•
Condenser Impeller Speed Controller
A solid state sensor reacting to the condenser coil temperature modulates the condenser impeller between minimum and maximum speed based on the coil temperature. This reduces noise levels, fan cycling, compressor cycling and prevents the unit from freezing.
•
Epoxy-Coated Condenser and Evaporator Coils
Condenser and Evaporator Coils are Epoxy-Coated. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
•
Filter
All Kooltronic filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reusable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacement filters are available and can be ordered online at kooltronic.com/spareparts.
•
Heavy-Duty Steel Shell
•
NEMA 12, 3R & 4 Ratings Maintained (UL50)
All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA Type 4 Enclosure Ratings.
•
Programmable Temperature Alarm
All models feature a programmable temperature alarm to alert if early action is required.
•
Programmable Thermostat
All models feature a programmable thermostat, allowing more accurate and versatile performance features.
•
Six-Foot [1.8m] (minimum) 3-Wire Power Cord
•
UL/CUL Listed
•
Adapter
A plate or plenum needed to replace older Kooltronic or competitor units.
•
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
•
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
•
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
•
Remote Monitoring
An optional feature for models with a Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required. This is accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
•
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
•
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
•
Special materials or finishes
•
Special motors, line cords or connectors
•
Stainless Steel Shell
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Dimensions, inches [mm], are for reference only and subject to change.
Model
Guideline
Dimensions
(H x W x D)*
CFM @0" S.P.
Guardian DP33
33.91 x 17.23 x 11.22
0
Guardian DP33LV
33.91 x 17.23 x 11.22
0
Guardian DP47
47.24 x 17.23 x 9.77
0
Guardian DP47LV
47.24 x 17.23 x 9.77
0
*See model specifics for drawings, dimensions, mounting or cutout plans.
2-D Drawing of the Mounting Plan
KNA4C7DP43L and/or LV Drawing of the Mounting Plan [40Kb]
3-D Solid Model
KNA4C7DP43L and/or LV Solid Model [5369Kb]
Brochure
Guardian/GuardianX 480 Volt Series Brochure [447Kb]
Guardian/GuardianX Series Brochure [447Kb]
Data Sheet
Guardian/GuardianX Series DP43 Product Data Sheet [404Kb]
GA Drawing
Guardian/GuardianX Series DP43 General Arrangement Drawing [99Kb]
Guardian/GuardianX Series DP43 General Arrangement Drawing (W/DIXELL) [74Kb]
Installation Instructions
Guardian/GuardianX Series DP43 Installation Instructions (2 pages) [448Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Slimkool Series Flyer [584Kb]
Guardian Series Brochure [256Kb]
Guardian Series Flyer [125Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller (Discontinued) [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
Guardian/GuardianX Series DP43 Operator's Manual [2703Kb]
Wiring Diagram
Guardian/GuardianX Series DP43 & DP47 Wiring Diagram (Low Temp. T-stat - Ladder) [56Kb]
Guardian/GuardianX Series DP43 & DP47 Wiring Diagram (Prgm. T-stat - Ladder) [48Kb]
Guardian/GuardianX Series K2A4C7DP43LF Wiring Diagram (Low Temp, T-stat - Point-to-Point) [69Kb]
Guardian/GuardianX Series K2NA4C7DP43L Wiring Diagram (Low Temp. T-stat - Point-to-Point) [72Kb]
Guardian/GuardianX Series K2NA4C7DP43L Wiring Diagram (Prgm. T-stat - Point-to-Point) [80Kb]
Guardian/GuardianX Series K2NA4C7DP43LD Wiring Diagram (Remote T-Stat (Prgm) - Point-to-Point) [79Kb]
Guardian/GuardianX Series KA4C7DP43LF-1 Wiring Diagram (Low Temp. T-stat - Point-to-Point) [73Kb]
Guardian/GuardianX Series KNA4C7DP43L Wiring Diagram (Low Temp. T-stat - Point-to-Point) [85Kb]
Guardian/GuardianX Series KNA4C7DP43L Wiring Diagram (Prgm. T-stat - Point-to-Point) [81Kb]
Guardian/GuardianX Series KNA4C7DP43L Wiring Diagram (Prgm. T-stat - Point-to-Point) [83Kb]
Guardian/GuardianX Series KNA4C7DP43LD Wiring Diagram (Remote T-stat (LT) - Point-to-Point) [74Kb]
Guardian/GuardianX Series KNA4C7DP43LD Wiring Diagram (Remote T-stat (Prgm) - Point-to-Point) [78Kb]