Contact Us! 609-466-3400
Toggle navigation
Home
Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Product Documentation
Industries
All Industries
Self-Service Kiosk
Food & Beverage
Water Treatment
Industrial Manufacturing
Medical Technology
Infrastructure
Hazardous Locations
Sizing
About Us
About Kooltronic
Kooltronic and the Environment
Virtual Tour
Kooltronic Timeline
Quality Standards
Services
Careers with Kooltronic
Contact Us
Sales Team
Contact Us
After Sale
K
are (ASK)
Blog
TrimLine Series WNP36
Water-Cooled Panel-Mounted Air Conditioners
Download
Product
Information
TECHNICAL DATA
Click to
Request
Quote
Model
BTU/H
Capacity
Water Flow (GPM)
@85°F Max.*
Volts
Hz
Running
Amps
Approx.
Weight
lbs
kg
KA4C6WNP36
6000
1.5
115/100
60/50
11.8
125
57
K2A4C6WNP36
6000
1.5
230/200
60/50
6.8
125
57
Rated for full capacity load at 85°F water. Usage will vary at lower load or cooler water conditions.
Rating shown is for operation at maximum water temperature.
230V models with Short Cycle Protector are not RoHS compliant.
Click on image for larger view
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
KA4C6WNP36
K2A4C6WNP36
BTU/H
Capacity:
6000
6000
Water Flow (GPM)
@85°F Max.*
1.5
1.5
Volts:
115/100
230/200
Hz:
60/50
60/50
Running
Amps:
11.8
6.8
Approx.
Weight lbs.:
125
125
Approx.
Weight kg.:
57
57
Rated for full capacity load at 85°F water. Usage will vary at lower load or cooler water conditions.
Rating shown is for operation at maximum water temperature.
230V models with Short Cycle Protector are not RoHS compliant.
STANDARD FEATURES
CFC-Free Refrigerant
CFC-free R134a Refrigerant is used
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
Excess Pressure Control
Low Temperature Control Thermostat
Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
Water Regulating Valve
ACCESSORIES AND OPTIONS
Adapter
A plate or plenum needed to replace older Kooltronic or competitor units.
Aluminum Shell
Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
Compressor Short Cycle Protector
Available as a Standard Feature on models with Programmable Thermostat. Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
Condenser Access Panel
Expressly designed for quick, convenient access to the condenser coil for easy cleaning and servicing. Recommended for units operating in dirty environments, the panel is easily removed and replaced by use of a few fasteners, without removal of the entire rear cover panel.
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
High Capacity Condensate Evaporator
Condensate evaporator kits are available for attachment to the bottom of Air-Cooled Panel Mounted Air Conditioners. Condensate is collected, vaporized and discharged to the surrounding air. All units include a safety overflow drain which discharges excessive condensate when required. Overflow may occur when cabinets are poorly sealed, or when cabinet doors are frequently opened, permitting the invasion of moisture-laden air.
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
Low Airflow Detector
Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Special controls or indicators
Special materials or finishes
Special motors, line cords or connectors
Stainless Steel Shell
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Enclosure Lights
AIRFLOW
Click on image for larger view
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details
.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
BTU/H Rating
TrimLine WNP33
32.88 x 12.38 x 8.88
4000
TrimLine WNP47
47.25 x 15.06 x 12.25
7000-12000
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
2-D Drawing of the Mounting Plan
KA4C5-6WNP36, K2A4C5-6WNP36 2-D Drawing of the Mounting Plan [32Kb]
3-D Solid Model
KA4C5-6WNP36, K2A4C5-6WNP36 3-D Solid Model [3300Kb]
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
KCH20 & KCH30 Product Data Sheet [60Kb]
WNP36 Product Data Sheet [73Kb]
GA Drawing
WNP36 GA Drawing [52Kb]
Installation Instructions
K_A4C_WNP36 Installation Instructions (2 pages) [146Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
KLLC100 Lead-Lag Controller (1 page) [58Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
TrimLine WNP33 & WNP36 Operator's Manual [169Kb]
Wiring Diagram
K_A4C5-7WNP28, 36, 52 & 59 Wiring Diagram (Ladder) [63Kb]
K2A4C4WNP36 Wiring Diagram (Ladder) [30Kb]
K2A4C4WNP36 Wiring Diagram (Point-to-Point) [43Kb]
KA4C2-5WNP36 Wiring Diagram (Point-to-Point) [47Kb]
KA4C2-5WNP36 Wiring Diagram (Point-to-Point) [47Kb]
KA4C4WNP36, KA4C6WNP36, K2A4C6WNP36 Wiring Diagram (Ladder) [44Kb]
KA4C5-6WNP36, K2A4C5-6WNP36 Wiring Diagram (Point-to-Point) [40Kb]
KA4C5-6WNP36, K2A4C5-6WNP36 Wiring Diagram (Point-to-Point) [42Kb]