Logo
Contact Us! 609-466-3400
  • Home
  • Products
    • Air Conditioners
    • Centrifugal & Packaged Blowers
    • Fans and Fan Trays
    • Heat Exchangers
    • Custom Cooling Design
    • Enclosure Accessories
    • Spare/Replacement Parts
    • Product Documentation
  • Industries
    • All Industries
    • Self-Service Kiosk
    • Food & Beverage
    • Water Treatment
    • Industrial Manufacturing
    • Medical Technology
    • Infrastructure
    • Hazardous Locations
  • Sizing
  • About Us
    • About Kooltronic
    • Kooltronic and the Environment
    • Virtual Tour
    • Kooltronic Timeline
    • Quality Standards
    • Services
    • Careers with Kooltronic
  • Contact Us
    • Sales Team
    • Contact Us
    • After Sale Kare (ASK)
  • Blog

GuardianX DP60 NEMA 4X
Air-Cooled Panel-Mounted Air Conditioners

download product information Download
Product
Information
TECHNICAL DATA

Click to
Request
Quote
ModelNEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzRunning
Amps
Approx.
Weight
°F°C
Max./Min.Max./Min.lbskg
Request RFQ linkK2NA6C26DP60LV4XListed2600022800131/-2055/-28208/2306024.0/21.2262120
Request RFQ linkK2NA6C26DP60LV4XListed2080018300131/-2055/-282205021262120
Request RFQ linkK3NA6C26DP60LV4XListed2600022240125/-2052/-28480608.7262120
Rating shown is for operation at maximum ambient temperature.

Click on image for larger view
Guardian DP60LV Air Conditioner photo
NEMA TYPE 4X
MAINTAINED

TECHNICAL DATA

Click to
Request
Quote:
Request RFQ linkRequest RFQ linkRequest RFQ link
Model
Number:
K2NA6C26DP60LVK2NA6C26DP60LVK3NA6C26DP60LV
NEMA
Rating:
4X4X4X
UL/CUL
Listed or
Recognized:
ListedListedListed
BTU/H
Capacity:
260002080026000
95/95 Rating
BTU/H:
228001830022240
Ambient
Temp °.F
Max./Min.:
131/-20131/-20125/-20
Ambient
Temp °.C
Max./Min.:
55/-2855/-2852/-28
Volts:208/230220480
Hz:605060
Running
Amps:
24.0/21.2218.7
Approx.
Weight lbs.:
262262262
Approx.
Weight kg.:
120120120
Rating shown is for operation at maximum ambient temperature.

STANDARD FEATURES

  • 208/230/220 & 480 Volt Models
  • Closed-Loop Cooling
    • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
  • Compressor Short Cycle Protector
    • Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
  • Condenser Blower Controller
  • Epoxy-Coated Condenser and Evaporator Coils
    • Condenser and Evaporator Coils are Epoxy-Coated. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • External junction box for permanent wiring connections
    • For 480 Volt models
  • Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Internal Corrosion Protection
    • NOTE: Internal Corrosion Protection is a Standard Feature on NEMA 4X models only. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
  • NEMA 4X Rating Maintained (UL50)
    • All GuardianX Series units are fully gasketed for tight, leakproof installation, in compliance with the NEMA Type 4X Enclosure Ratings.
  • Programmable Temperature Alarm
    • All models feature a programmable temperature alarm to alert if early action is required.
  • Programmable Thermostat
    • All models feature a programmable thermostat, allowing more accurate and versatile performance features.
  • Six-Foot [1.8m] (minimum) 3-Wire Power Cord
  • Stainless Steel Shell
    • For applications in corrosive or other hostile environments such as those requiring Internal Corrosion Resistant Coatings, especially where chemical/moisture combinations are present.
  • UL/CUL Listed
  • Zero ODP Refrigerant
    • R410a, an HFC having zero ozone depleting potential.

ACCESSORIES AND OPTIONS

  • Adapter
    • A plate or plenum needed to replace older Kooltronic or competitor units.
  • Enclosure Heater
    • Eliminates damaging condensation, increasing reliability of electrical enclosure components.
  • Filter Recoating Adhesive
    • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
  • Click for more info.Lead-Lag Controller
  • Remote Monitoring
    • An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
  • Remote Thermostat Relay
    • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
  • Replacement Filters
    • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
  • Special materials or finishes
  • Special motors, line cords or connectors

For GuardianX DP60 models the filter part number is 19381F. The DP60 uses two filters.


Enclosure Lights

AIRFLOW
Click on image for larger view

Guardian DP60LV Air Conditioner isometric illustration

PERFORMANCE

Guardian DP60LV Air Conditioner performance chart

Guardian DP60LV Air Conditioner performance chart #2

GENERAL ARRANGEMENT
Click on image for larger view

Guardian DP60LV Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view

Guardian DP60LV Air Conditioner general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details.

SIMILAR MODELS

ModelGuideline
Dimensions
(H x W x D)*
BTU/H Rating
Guardian DP5050.05 x 20.14 x 12.0513100-14000
Guardian DP50LV50.05 x 20.14 x 12.0513100-14000
Guardian DP5352.60 x 22.14 x 13.0214400-18000
Guardian DP53LV52.60 x 22.14 x 13.0214400-18000
*See model specifics for drawings, dimensions, mounting or cutout plans.

DOCUMENTS

  • 2-D Drawing of the Mounting Plan
    Guardian/GuardianX Series 480V K3NA6C26DP60L-LV 2-D Drawing of the Mounting Plan [24096Kb]
    K2NA6C26DP60L and/or LV Drawing of the Mounting Plan [33Kb]
  • 3-D Solid Model
    Guardian/GuardianX Series 480V K3NA6C26DP60L-LV 3-D Solid Model [33Kb]
    K2NA6C26DP60L and/or LV Solid Model [21947Kb]
  • Brochure
    Guardian/GuardianX Series Brochure [447Kb]
  • Data Sheet
    KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
    Guardian/GuardianX Series 480 DP60 Data Sheet [257Kb]
    Guardian/GuardianX Series DP60 Data Sheet [257Kb]
  • GA Drawing
    Guardian/GuardianX Series 480V DP60 General Arrangement Drawing [84Kb]
    Guardian/GuardianX Series 480V DP60 General Arrangement Drawing W/ Programmable T-stat [95Kb]
    Guardian/GuardianX Series DP60 General Arrangement Drawing [236Kb]
    Guardian/GuardianX Series DP60 General Arrangement Drawing W/ Programmable T-stat [90Kb]
  • Installation Instructions
    Guardian/GuardianX Series 480V DP60 Installation Instructions (2 pages) [173Kb]
    Guardian/GuardianX Series DP60 Installation Instructions (2 pages) [194Kb]
  • Literature
    Air Conditioner Quick-Sheet [105Kb]
    Condensate Evaporator Kits [241Kb]
    Condensation and Electronics [3983Kb]
    Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
    Hazardous Location Series White Paper [234Kb]
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    KLLC100 Lead-Lag Controller (1 page) [58Kb]
    Guardian Series Brochure [256Kb]
    Guardian Series Flyer [125Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    Airflow Switch Data Sheet [159Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
  • Operator's Manual
    KLLC100 Lead-Lag Controller [38Kb]
    KLLC480 Lead-Lag Controller [79Kb]
    Guardian/GuardianX Series 480V DP60 Operator's Manual [574Kb]
    Guardian/GuardianX Series DP60 Operator's Manual [481Kb]
  • Wiring Diagram
    Guardian/GuardianX Series 480V K3NA6C26DP60L Wiring Diagram (Ladder) [57Kb]
    Guardian/GuardianX Series 480V K3NA6C26DP60L Wiring Diagram (Ladder) [59Kb]
    Guardian/GuardianX Series 480V K3NA6C26DP60L Wiring Diagram (Point-to-Point) [92Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Low Temp. T-stat - Ladder) [46Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Low Temp. T-stat - Point-to-Point) [46Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Prgm. T-stat - Ladder) [59Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Prgm. T-stat - Point-to-Point) [75Kb]
    Guardian/GuardianX Series K2NA6C26DP60L1 Wiring Diagram (Remote T-stat (Prgm.) - Point-to-Point) [91Kb]
    Guardian/GuardianX Series K2NA6C26DP60LF & G Wiring Diagram (Low Temp. T-stat - Point-to-Point) [85Kb]
Footer logo
Wednesday, January 27, 2021  
©2021 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
Contact Us
Popular links:

Product Sizing and Selection
Catalogs/Brochures
Virtual Plant Tour
Sales Team
Kooltronic Blog

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo