    • Air Conditioners
    • Centrifugal & Packaged Blowers
    • Fans and Fan Trays
    • Heat Exchangers
    • Custom Cooling Design
    • Enclosure Accessories
    • Spare/Replacement Parts
    • Contract Manufacturing Services
  • Industries
    • All Industries
    • Battery Energy Storage Systems
    • Kiosks, ATMs & Smart Lockers
    • Medical Technology
    • Wastewater & Water Treatment
    • Transportation
    • Industrial Manufacturing
    • Hazardous Locations
    • Food & Beverage
    • Military & Avionics
    • Infrastructure
    • Security Detection & Surveillance
  • Sizing
  • Resources
    • Cooling Solutions Blog
    • MyKooltronic Customer Portal
    • Product Documentation
    • Whitepapers
    • An Intro to Closed Loop Cooling
    • Quality & Compliance Certficates ►
      • ISO 9001:2015 Certificate
      • UL Client Test Data Program Certificate
      • ROHS 3 Compliance Statement
      • REACH Declaration
      • Kooltronic Quality Policy
      • Conflict Minerals Report
    • Credit Application
    • Credit Reference Form
  • About Us
    • About Kooltronic
    • News & Announcements
    • Eco-Friendly Practices
    • Interactive Timeline
    • Virtual Tour
    • Our Core Values
    • Careers with Kooltronic
  • Contact Us
    • Send Us a Message
    • Sales Team
    • After Sale Kare (ASK)
  • Shopping Cart
  • RFQ Cart
  • MyKooltronic
{1}
##LOC[OK]##
{1}
##LOC[OK]## ##LOC[Cancel]##
{1}
##LOC[OK]## ##LOC[Cancel]##

GuardianX DP60 NEMA 4X
Air-Cooled Panel-Mounted Air Conditioners

Product Photo Thumbnail
LightBox Active Image

Image 1 of 1
NEMA TYPE 4X
MAINTAINED
Select Model Type

Electrical (Volts/Hz):

ModelNEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.VoltsHzRunning
Amps
Approx.
Weight
°F°C
Max./Min.Max./Min.lbskg
K2NA6C26DP60LV4XListed2600018279129/-2054/-282306024.7262120
K3NA6C26DP60LV4XListed2600022242125/-2052/-28480608.61262120
Rating shown is for operation at maximum ambient temperature.

TECHNICAL DATA

ModelNEMA
Rating
BTU/H
Capacity
Volts/Hz
K2NA6C26DP60LV4X26000230/60V, 60Hz
UL/CUL Listed or Recognized: Listed
95/95 BTU Rating: 18279
Ambient Max./Min. °F: 129/-20
Ambient Max./Min. °C: 54/-29
Running Amps: 24.7
Approx. weight: 262 lbs. (119 kg)
K3NA6C26DP60LV4X26000480/60V, 60Hz
UL/CUL Listed or Recognized: Listed
95/95 BTU Rating: 22242
Ambient Max./Min. °F: 125/-20
Ambient Max./Min. °C: 52/-29
Running Amps: 8.61
Approx. weight: 262 lbs. (119 kg)
Rating shown is for operation at maximum ambient temperature.
  • Standard Features
  • Accessories & Options
  • Airflow Diagram
  • Performance
  • Arrangement
  • Similar Models
  • Documents
• 230 and 480 Volt Models
• Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
• Compressor Short Cycle Protector
Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
• Condenser Blower Controller
• Epoxy-Coated Condenser and Evaporator Coils
Condenser and Evaporator Coils are Epoxy-Coated. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
• External junction box for permanent wiring connections
For 480 Volt models
• Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
• Internal Corrosion Protection
NOTE: Internal Corrosion Protection is a Standard Feature on NEMA 4X models only. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
• NEMA 4X Rating Maintained (UL50)
All GuardianX Series units are fully gasketed for tight, leakproof installation, in compliance with the NEMA Type 4X Enclosure Ratings.
• Programmable Temperature Alarm
All models feature a programmable temperature alarm to alert if early action is required.
• Programmable Thermostat
All models feature a programmable thermostat, allowing more accurate and versatile performance features.
• Six-Foot [1.8m] (minimum) 3-Wire Power Cord
• Stainless Steel Shell
For applications in corrosive or other hostile environments such as those requiring Internal Corrosion Resistant Coatings, especially where chemical/moisture combinations are present.
• UL/CUL Listed
• Zero ODP Refrigerant
R410a, an HFC having zero ozone depleting potential.

• Adapter
A plate or plenum needed to replace older Kooltronic or competitor units.
• Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
• Remote Monitoring
An optional feature for models with a Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required. This is accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
• Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
• Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
• Special materials or finishes
• Special motors, line cords or connectors
Click on image for larger view
Airflow Diagram Thumbnail
LightBox Active Image

Image 1 of 1
Guardian DP60LVairflow diagram

Dimensions, inches [mm], are for reference only and subject to change.

Guardian DP60LV performance chart

Guardian DP60LV performance chart #2

Click on image for larger view
General Arrangement Thumbnail
LightBox Active Image

Image 1 of 1
Guardian DP60LV general arrangement drawing
Dimensions, inches [mm], are for reference only and subject to change.

Dimensions, inches [mm], are for reference only and subject to change.
ModelGuideline
Dimensions
(H x W x D)*
CFM @0" S.P.
Guardian DP5050.05 x 20.14 x 12.050
Guardian DP50LV50.05 x 20.14 x 12.050
Guardian DP5352.60 x 22.14 x 13.020
Guardian DP53LV52.60 x 22.14 x 13.020
*See model specifics for drawings, dimensions, mounting or cutout plans.
  • 2-D Drawing of the Mounting Plan
    Guardian/GuardianX Series 480V K3NA6C26DP60L-LV 2-D Drawing of the Mounting Plan [24096Kb]
    K2NA6C26DP60L and/or LV Drawing of the Mounting Plan [33Kb]
  • 3-D Solid Model
    Guardian/GuardianX Series 480V K3NA6C26DP60L-LV 3-D Solid Model [33Kb]
    K2NA6C26DP60L and/or LV Solid Model [21947Kb]
  • Brochure
    Guardian/GuardianX 480 Volt Series Brochure [447Kb]
    Guardian/GuardianX Series Brochure [447Kb]
  • Data Sheet
    Guardian/GuardianX Series 480 DP60 Data Sheet [1623Kb]
    Guardian/GuardianX Series DP60 Data Sheet [1648Kb]
  • GA Drawing
    Guardian/GuardianX Series 480V DP60 General Arrangement Drawing [84Kb]
    Guardian/GuardianX Series 480V DP60 General Arrangement Drawing W/ Programmable T-stat [95Kb]
    Guardian/GuardianX Series DP60 General Arrangement Drawing [236Kb]
    Guardian/GuardianX Series DP60 General Arrangement Drawing W/ Programmable T-stat [90Kb]
  • Installation Instructions
    Guardian/GuardianX Series 480V DP60 Installation Instructions (2 pages) [173Kb]
    Guardian/GuardianX Series DP60 Installation Instructions (2 pages) [393Kb]
  • Literature
    Air Conditioner Quick-Sheet [105Kb]
    Condensate Evaporator Kits [241Kb]
    Condensation and Electronics [3983Kb]
    Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
    Hazardous Location Series White Paper [234Kb]
    Increasing the Lifespan and Reliability of Electrical Components [212Kb]
    Slimkool Series Flyer [584Kb]
    Guardian Series Brochure [256Kb]
    Guardian Series Flyer [125Kb]
    Kooltronic Custom Capabilities Flyer [2194Kb]
    Kooltronic Custom Cooling Medical Flyer [211Kb]
    Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
    Kooltronic Refrigeration System Manufacturing [55Kb]
    Kooltronic Standard Warranty [55Kb]
    Kooltronic Unit Longevity Press Release [167Kb]
    NEMA Enclosure Ratings [91Kb]
    Short-Form Catalog (16 pages) [897Kb]
    Airflow Switch Data Sheet [159Kb]
    Laboratory Environmental Testing Services [157Kb]
    Powder Paint Application Facilities Flyer [165Kb]
  • Operator's Manual
    KLLC100 Lead-Lag Controller (Discontinued) [38Kb]
    KLLC480 Lead-Lag Controller [79Kb]
    Guardian/GuardianX Series 480V DP60 Operator's Manual [3181Kb]
    Guardian/GuardianX Series DP60 Operator's Manual [3182Kb]
  • Wiring Diagram
    Guardian/GuardianX Series 480V K3NA6C26DP60L Wiring Diagram (Ladder) [57Kb]
    Guardian/GuardianX Series 480V K3NA6C26DP60L Wiring Diagram (Ladder) [59Kb]
    Guardian/GuardianX Series 480V K3NA6C26DP60L Wiring Diagram (Point-to-Point) [92Kb]
    Guardian/GuardianX Series DP60 Wiring Diagram (ladder) [54Kb]
    Guardian/GuardianX Series DP60 Wiring Diagram (point-to-point) [79Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Low Temp. T-stat - Ladder) [46Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Low Temp. T-stat - Point-to-Point) [46Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Prgm. T-stat - Ladder) [59Kb]
    Guardian/GuardianX Series K2NA6C26DP60L Wiring Diagram (Prgm. T-stat - Point-to-Point) [75Kb]
    Guardian/GuardianX Series K2NA6C26DP60L1 Wiring Diagram (Remote T-stat (Prgm.) - Point-to-Point) [91Kb]
    Guardian/GuardianX Series K2NA6C26DP60LF & G Wiring Diagram (Low Temp. T-stat - Point-to-Point) [85Kb]
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details.

Footer logo
Monday, May 12, 2025  
©2025 Kooltronic, Inc. - All rights reserved.
Terms of Use
Contact Info:
Kooltronic, Inc.
30 Pennington-Hopewell Road
Pennington, NJ 08534 USA
609-466-3400
800-321-KOOL
609-466-1114 (fax)
Contact Us
Popular links:

Home
Product Sizing and Selection
Catalogs/Brochures
Sales Team
Careers
MyKooltronic

LinkedIn profile icon Twitter profile icon YouTube profile icon Facebook profile icon Kooltronic Blog icon
ISO-9001 logo Made In USA logo