Contact Us! 609-466-3400
Toggle navigation
Home
Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Product Documentation
Industries
All Industries
Self-Service Kiosk
Food & Beverage
Water Treatment
Industrial Manufacturing
Medical Technology
Infrastructure
Hazardous Locations
Sizing
About Us
About Kooltronic
Kooltronic and the Environment
Virtual Tour
Kooltronic Timeline
Quality Standards
Services
Careers with Kooltronic
Contact Us
Sales Team
Contact Us
After Sale
K
are (ASK)
Blog
Intrepid Series EP56 Outdoor
Air-Cooled Panel-Mounted Air Conditioners
Download
Product
Information
TECHNICAL DATA
Click to
Request
Quote
Model
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Cooling
Amps
Heating
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
K2A6C30EP56BR
30000
28000
131/0
55/-17
230
60
25.5
15.3
304
139
K2A6C30EP56TR
30000
28000
131/0
55/-17
230
60
25.5
15.3
302
138
Rating shown is for operation at maximum ambient temperature.
230V models with Short Cycle Protector are not RoHS compliant.
TR in model number is Top Evaporator Discharge.
BR in model number is Bottom Evaporator Discharge.
Click on image for larger view
NEMA
TYPE 3R, 12 & 1
MAINTAINED
TECHNICAL DATA
Click to
Request
Quote:
Model
Number:
K2A6C30EP56BR
K2A6C30EP56TR
BTU/H
Capacity:
30000
30000
95/95 Rating
BTU/H:
28000
28000
Ambient
Temp °.F
Max./Min.:
131/0
131/0
Ambient
Temp °.C
Max./Min.:
55/-17
55/-17
Volts:
230
230
Hz:
60
60
Cooling
Amps:
25.5
25.5
Heating
Amps:
15.3
15.3
Approx.
Weight lbs.:
304
302
Approx.
Weight kg.:
139
138
Rating shown is for operation at maximum ambient temperature.
230V models with Short Cycle Protector are not RoHS compliant.
TR in model number is Top Evaporator Discharge.
BR in model number is Bottom Evaporator Discharge.
STANDARD FEATURES
Available in either top or bottom evaporator air discharge model
Baked Powder Finish
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
Condenser Blower Speed Controller
A speed control sensing bulb located in the condenser air outlet area switches the condenser blower between minimum and maximum speed based on the ambient temperature. This reduces noise levels, fan cycling, compressor cycling and prevents the unit from freezing.
Crankcase Compressor Heater
120V or 240V heater attached to the compressor crankcase to maintain appropriate temperatures during cold operating conditions.
Heavy-Duty Steel Shell
Low Temperature Control Thermostat
Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
NEMA 12, 3R & 1 Ratings Maintained (UL50)
Fully gasketed for tight, leakproof installation, in compliance with the NEMA 12, 3R & 1 Enclosure Ratings.
Six-Foot [1.8m] (minimum) 3-Wire Power Cord
Tamper-resistant hardware
UL/CUL Recognized
Zero ODP Refrigerant
R410a, an HFC having zero ozone depleting potential.
ACCESSORIES AND OPTIONS
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Lead-Lag Controller
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Special paint finishes
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Enclosure Lights
AIRFLOW
Click on image for larger view
PERFORMANCE
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
GENERAL ARRANGEMENT
Click on image for larger view
Dimensions, inches [mm], are for reference only and subject to change.
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details
.
SIMILAR MODELS
Model
Guideline
Dimensions
(H x W x D)*
BTU/H Rating
Guardian DP60LV
60.20 x 24.14 x 13.02
20800-26000
*See model specifics for drawings, dimensions, mounting or cutout plans.
DOCUMENTS
2-D Drawing of the Mounting Plan
K2A6C30EP56_R 2-D Drawing of the Mounting Plan [36Kb]
3-D Solid Model
K2A6C30EP56_R 3-D Solid Model [8910Kb]
Data Sheet
KLLC100-480 Lead-Lag Controller Product Data Sheet [58Kb]
EP56 Product Data Sheet [220Kb]
EP62 Product Data Sheet (Discontinued) [347Kb]
GA Drawing
EP56BR General Arrangement Drawing [182Kb]
K2A6C30EP56TR-4 General Arrangement Drawing [113Kb]
Installation Instructions
K2A6C30EP56BR Installation Instructions (2 pages) [127Kb]
K2A6C30EP56TR Installation Instructions (2 pages) [126Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
KLLC100 Lead-Lag Controller (1 page) [58Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Design Guide/Catalog (215 pages) [24440Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
EP62 Operator's Manual (Discontinued) [411Kb]
Intrepid EP56 Operator's Manual [290Kb]
K2A6C30EP56TR-4 Operator's Manual [798Kb]
Wiring Diagram
K2A6C30EP56_R Wiring Diagram (Ladder) [53Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [64Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [66Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [62Kb]
K2A6C30EP56BR-2,-3 Wiring Diagram (Point-to-Point) [75Kb]
K2A6C30EP56TR-4 Wiring Diagram (Point-to-Point) [85Kb]